S1D15E06 Series
10. TIMING CHARACTERISTICS
(1) System path read/write characteristics 1 (80 system MPU)
A0
t
AW8
t
AH8
CS1
(CS2=“1”)
t
CYC8
*1
t
CCLR, tCCLW
WR, RD
t
CCHR, tCCHW
CS1
(CS2=“1”)
t
f
t
r
*2
WR, RD
t
DS8
t
DH8
D0 to D7
(Write)
t
ACC8
t
OH8
D0 to D7
(Read)
Fig. 10.1
Table 10.1.1
[VDD = 3.0V to 3.6V, Ta = –40 to +85°C]
Specified value
Parameter
Signal Symbol
Condition
Unit
Min.
Max.
Address hold time
Address setup time
A0
tAH8
tAW8
0
0
—
—
ns
System write cycle time
System read cycle time
WR
RD
tWCYC8
tRCYC8
200
300
—
—
Control LOW-pulse width (Write)
WR
RD
WR
RD
tCCLW
tCCLR
tCCHW
tCCHR
60
100
60
—
—
—
—
Control LOW-pulse width (Read)
Control HIGH-pulse width (Write)
Control HIGH-pulse width (Read)
100
Data setup time
Data hold time
D0 to D7
tDS8
tDH8
20
10
—
—
RD access time
Output disable time
tACC8
tOH8
CL=100pF
—
10
80
80
58
EPSON
Rev. 2.1