S1D15E06 Series
• Start point (block) register set parameter
Use this parameter to set 6-bit data in the start point (block) register. Then one of 33 start point blocks will be determined.
* Use the Display Start Line Set command (6) for display scroll. Do not use this command for display scroll.
P25 P24 P23 P22 P21 P20
Start piont setting
0 (COM0 to 3)
1 (COM4 to 7)
2 (COM8 to 11)
↓
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
↓
0
1
1
0
1
0
1
0
1
0
1
0
31 (COM124 to 127)
32 (COM128 to 131)
Set to 0 block (D7 to D0: ***00000) at the time of resetting
* Voltage optimum to liquid crystal drive is changed when the duty is changed. Use the electronic volume and set the
voltage to get the optimum display.
• Duty command setup example
1. Duty 1/88 When 1 (COM4 to COM7) is specified as the start point (block)
Display area COM4 to COM91
2. Duty 1/68 When 26 (COM104 to COM107) is specified as the start point (block)
Display area COM104 to COM131 and COM0 to COM39
* If the COM pin is not shared by the master and slave in the master/slave 2-chip operation (for vertical drive such as
SEG132, COM80+COM80), the same duty must be used on the master and slave. Otherwise, display contrast will
be different on the master and slave. When you want to disable display on either the master and slave, use the display
OFF Mode Select command to set the side you want to disable, so that VC level is output.
(19) Partial Display ON/OFF
The LCD partial display is turned on or off by this command.
E
RD
R/W
WR
A0
D7
D6
D5
D4
D3
D2
D1
D0
0
Partial display
0
1
0
1
0
0
1
0
1
1
OFF
ON
1
(20) Partial Display Set
This command sets the LCD partial display area. Duty is placed in the state selected by the Duty Set command. When
partial display is switched by this command, liquid crystal drive voltage need not be changed. For details, see the
description of “6.2.7 Partial Display” in the Function Description.
E
RD
R/W
WR
A0
0
D7
D6
D5
D4
D3
D2
D1
D0
Partial display
Command
1
1
1
0
0
0
0
0
1
1
0
0
1
0
1
P17 P16 P15 P14 P13 P12 P11 P10
P27 P26 P25 P24 P23 P22 P21 P20
Display start line
Display line count
1
P17 P16 P15 P14 P13 P12 P11 P10
Display start line
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
↓
0
1
0
0
1
2
↓
1
1
0
0
0
0
0
0
0
0
0
0
1
1
0
1
131
132
Rev. 2.1
EPSON
35