S1D15E06 Series
(14) n-line ON/OFF
This command provides ON/OFF control of n-line inverting drive.
E
RD
R/W
WR
A0
D7
D6
D5
D4
D3
D2
D1
D0
0
n-line
OFF
ON
0
1
0
1
1
1
0
0
1
0
1
(15) Display Mode
This command sets the display mode. 4 gray-scale and binary display each have a different RAM configuration.
For details, see the description of “6.2.1 Display Data RAM” in the Function Description.
E
RD
R/W
WR
A0
0
D7
0
D6
1
D5
1
D4
0
D3
0
D2
1
D1
1
D0
0
Display mode
Command
1
1
0
0
1
*
*
*
*
*
*
P1
P0
Display mode
*: denote invalid bits.
P1
0
P0
0
Display mode
4gray-scale
0
1
Binary value
Set to 4 gray-scale (D1, D0) = (0, 0) at the time of resetting.
(16) Gray-scale Pattern Set
This command sets the level of gray-scale.
E
RD
R/W
WR
A0
0
D7
0
D6
0
D5
1
D4
1
D3
1
D2
0
D1
0
D0 Gray-scale pattern
1
1
0
0
1
Command
1
*
P6
P5
P4
*
P2
P1
P0
Selection of
gray-scale level
* (P6, P5, P4) : Selects the level of gray-scale bit (1, 0)
* (P2, P1, P0) : Selects the level of gray-scale bit (0, 1)
Gray-scale bit (1, 0)
Gray-scale bit (0, 1)
P6
0
P5
0
P4
1
P2
–
P1
–
P0 Level of gray-scale
–
–
–
–
–
–
White
0
1
0
–
–
↓
↓
–
1
1
0
–
–
–
–
Black
P6
–
P5
–
P4
–
P2
0
P1
0
P0 Level of gray-scale
–
–
–
–
1
0
White
–
–
–
0
1
↓
↓
–
–
–
–
–
1
1
0
Black
32
EPSON
Rev. 2.1