S1D15E06 Series
(22) End
This command releases the read modify write mode and gets column address back to the initial address of the mode.
E
RD
R/W
WR
A0
D7
D6
D5
D4
D3
D2
D1
D0
0
1
0
1
1
1
0
1
1
1
0
Return
Column address
N
N+1
N+2
N+3
• • •
N+m
N
End
Set read-modify-write mode
Fig. 7.3
(23) Built-in Oscillator Circuit ON/OFF
This command starts the built-in oscillator circuit operation. It is enabled only in the master operation mode (M/S =
HIGH) when built-in oscillator circuit is valid (CLS = HIGH).
When the built-in power supply is used, the Oscillator Circuit ON command must be executed before the Power Control
Set command. (See the description of “(16) power control command”). If the built-in oscillator circuit is turned off
when the built-in power supply is used, display failure may occur.
E
RD
R/W
WR
Built-in oscillator
circuit
A0
D7
D6
D5
D4
D3
D2
D1
D0
0
0
1
0
1
0
1
0
1
0
1
OFF
ON
1
Rev. 2.1
EPSON