Epson Research and Development  
Page 13  
Vancouver Design Center  
The S1D13506 may use as many as three input clocks or as few as one. The more clocks  
used the greater the flexibility of choice in display type and memory speed.  
CLKI  
This setting determines the frequency of CLKI. CLKI is  
typically used for the panel and CRT/TV pixel clocks.  
Select Autoto have the CLKI frequency determined  
automatically based on settings made on other configu-  
ration tabs. After completing the other configurations,  
the required CLKI frequency will be displayed in blue  
in the Auto section.  
If the CLKI frequency must be fixed to a particular rate,  
set this value by selecting a preset frequency from the  
drop down list or entering the desired frequency in  
MHz.  
CLKI2  
This setting determines the frequency of CLKI2. If the  
MediaPlug interface is required, CLKI2 is typically  
used as the clock source.  
Select Autoto have the CLKI2 frequency determined  
automatically based on settings made on other configu-  
ration tabs. After completing the other configurations,  
the required CLKI2 frequency will be displayed in blue  
in the Auto section.  
If the CLKI2 frequency must be fixed to a particular  
rate, set this value by selecting a preset frequency from  
the drop down list or entering the desired frequency in  
MHz.  
BUSCLK  
This setting determines the frequency of the bus  
interface clock (BUSCLK). This value is required for  
calculating internal divisors which will yield the best  
performance.  
The BUSCLK frequency must be fixed to a particular  
rate. Set this value by selecting a preset frequency from  
the drop down list or entering the desired frequency in  
MHz.  
BCLK=BUSCLK/2  
Indicates the BCLK to BUSCLK ratio. This ratio is set  
at RESET# by the configuration pin CONF5.  
Under normal circumstances BCLK = BUSCLK. This  
option is only for configuring Toshiba/Philips inter-  
faces when DCLKOUT is connected to the S1D13506  
BUSCLK signal.  
13506CFG Configuration Program  
Issue Date: 01/03/14  
S1D13506  
X25B-B-001-02  