 浏览型号EN29GL064T-70TIP的Datasheet PDF文件第32页浏览型号EN29GL064T-70TIP的Datasheet PDF文件第33页浏览型号EN29GL064T-70TIP的Datasheet PDF文件第34页浏览型号EN29GL064T-70TIP的Datasheet PDF文件第35页浏览型号EN29GL064T-70TIP的Datasheet PDF文件第37页浏览型号EN29GL064T-70TIP的Datasheet PDF文件第38页浏览型号EN29GL064T-70TIP的Datasheet PDF文件第39页浏览型号EN29GL064T-70TIP的Datasheet PDF文件第40页  
Preliminary EN29GL064  
Dynamic Protection Bits  
Dynamic Protection Bits are volatile and unique for each sector and can be individually modified. DYBs  
only control the protection scheme for unprotected sectors that have their PPBs cleared (erased to “1”).  
By issuing the DYB Set or Clear command sequences, the DYBs are set (programmed to “0”) or cleared  
(erased to “1”), thus placing each sector in the protected or unprotected state respectively. This feature  
allows software to easily protect sectors against inadvertent changes yet does not prevent the easy  
removal of protection when changes are needed.  
Notes  
1. The DYBs can be set (programmed to “0”) or cleared (erased to “1”) as often as needed. When the  
parts are first shipped, the PPBs are cleared (erased to “1”) and upon power up or reset, the  
DYBs can be set or cleared depending upon the ordering option chosen.  
2. If the option to clear the DYBs after power up is chosen, (erased to “1”), then the sectorsmay be  
modified depending upon the PPB state of that sector (see Table 8).  
3. The sectors would be in the protected state If the option to set the DYBs after power up is chosen  
(programmed to “0”).  
4. It is possible to have sectors that are persistently locked with sectors that are left in the dynamic  
state.  
5. The DYB Set or Clear commands for the dynamic sectors signify protected or unprotectedstate of  
the sectors respectively. However, if there is a need to change the status of the persistently locked  
sectors, a few more steps are required. First, the PPB Lock Bit must be cleared by either putting  
the device through a power-cycle, or hardware reset. The PPBs can then be changed to reflect the  
desired settings. Setting the PPB Lock Bit once again locks the PPBs, and the device operates  
normally again.  
6. To achieve the best protection, it is recommended to execute the PPB Lock Bit Set command early  
in the boot code and protect the boot code by holding WP#/ACC = VIL. Note that the PPB and DYB  
bits have the same function when WP#/ACC = VHH as they do when ACC =VIH.  
Persistent Protection Bit Lock Bit  
The Persistent Protection Bit Lock Bit is a global volatile bit for all sectors. When set (programmed to  
“0”), it locks all PPBs and when cleared (programmed to “1”), allows the PPBs to be changed. There is  
only one PPB Lock Bit per device.  
Notes  
1. No software command sequence unlocks this bit unless the device is in the password protection  
mode; only a hardware reset or a power-up clears this bit.  
2. The PPB Lock Bit must be set (programmed to “0”) only after all PPBs are configured to the  
desired settings.  