 浏览型号EDS1216AABH-75-E的Datasheet PDF文件第30页浏览型号EDS1216AABH-75-E的Datasheet PDF文件第31页浏览型号EDS1216AABH-75-E的Datasheet PDF文件第32页浏览型号EDS1216AABH-75-E的Datasheet PDF文件第33页浏览型号EDS1216AABH-75-E的Datasheet PDF文件第35页浏览型号EDS1216AABH-75-E的Datasheet PDF文件第36页浏览型号EDS1216AABH-75-E的Datasheet PDF文件第37页浏览型号EDS1216AABH-75-E的Datasheet PDF文件第38页  
EDS1216AABH, EDS1216CABH  
Read with auto precharge to Write command interval  
1. Different bank: When some banks are in the active state, the second write command (another bank) is executed.  
However, UDQM and LDQM must be set High so that the output buffer becomes High-Z before data input. The  
internal auto-precharge of one bank starts at the next clock of the second command.  
CLK  
Command  
BS  
READA  
WRIT  
in B0  
CL = 2  
CL = 3  
UDQM  
LDQM  
DQ (input)  
in B1  
in B2  
in B3  
DQ (output)  
High-Z  
BL = 4  
bank0  
ReadA  
bank3  
Write  
Note: Internal auto-precharge starts at the timing indicated by "  
".  
Read with Auto Precharge to Write Command Interval (Different bank)  
2. Same bank: The consecutive write command from read with auto precharge (the same bank) is illegal. It is  
necessary to separate the two commands with a bank active command.  
Write with auto precharge to Read command interval  
1. Different bank: When some banks are in the active state, the second read command (another bank) is executed.  
However, in case of a burst write, data will continue to be written until one clock before the read command is  
executed. The internal auto-precharge of one bank starts at 2 clocks later from the second command.  
CLK  
Command  
BS  
WRITA  
in A0  
READ  
UDQM  
LDQM  
DQ (input)  
DQ (output)  
out B0  
out B1  
out B2 out B3  
CL = 3  
BL = 4  
bank0  
WriteA  
bank3  
Read  
Note: Internal auto-precharge starts at the timing indicated by "  
".  
Write with Auto Precharge to Read Command Interval (Different bank)  
2. Same bank: The consecutive read command from write with auto precharge (the same bank) is illegal. It is  
necessary to separate the two commands with a bank active command.  
Data Sheet E0410E40 (Ver. 4.0)  