Symbol
Tr
Tf
Parameter
Output rise time
Output Fall Time
Prop delay,
A429 to LH output
Prop delay,
A429 to HL output
Matching of
TPLH and TPHL
Prop delay,
TESTA/B to LH output
Prop delay,
Conditions (1,2)
CL = 60 pF (4)
CL = 60 pF (4)
A429 In = 0 to 10V (4)
CAPA, CAPB, OUT CL = 60 pF
A429 In = 0 to 10V (4)
CAPA, CAPB, OUT CL = 60 pF
|TPLH-TPHL| (4)
Min.
10
Max.
70
Units
ns
ns
10
70
1500
TPLH
ns
TPHL
DTP
1500
500
ns
ns
ns
ns
TPTLH
CL = 60 pF, VIN = 0.8V/2.0V (4)
CL = 60 pF, VIN = 0.8V/2.0V (4)
400
800
600
TPTHL
1300
TESTA/B to HL output
Notes:
1. Unless otherwise noted, currents flowing in to DUT are positive, Currents flowing out of DUT are negative, Voltages are
referenced to Ground.
2. Unless otherwise noted, Tcase = -55°C to +125°C for -xMx, -40°C to +125°C for -xAx, and -55°C to +85°C for –xEx versions;
+VS = +13.5 to 16.5V, -Vs = -13.5 to –16.5V, +VL = 4.5 to 5.5V.
3. Guaranteed by design. Not production tested.
4. Sample tested.
AC Test Waveforms
©2012 Device Engineering Inc
Page 5 of 11
DS-MW-03283-01 Rev L
12/12/2012