6000 Count AUTO DMM
4.3 DIGIT 3 – DIGIT 0
Digit 3 is the most significant digit on the LCD panel, and digit 0 is the least significant
digit. When the LCD panel shows OL, the serial port outputs 6000.
Digit
Code
0
1
2
3
4
5
6
7
8
9
0110000
0110001
0110010
0110011
0110100
0110101
0110110
0110111
0111000
0111001
Because the cycle time of measurement for continuity/diode mode is only 90ms, the
least significant digit may not be accurate.
4.4 STATUS
The format of this shown below. The Judge field is meaningful only when the Function
packet indicates Temperature mode. In Temperature mode, judge is 1 if the unit is ℃
and is 0 of the unit is ℉ . Sign field indicates whether the minus sign on the LCD
panel is on or off. BATT field is one of battery low condition is true. OL indicates input
overflow.
0
1
1
Judge
BIT 3
Sign
BIT 2
BATT
BIT1
OL
BIT 0
BIT 6
BIT 5
BIT 4
4.5 OPTION 1
This packet is not used.
MAX
BIT 2
0
1
1
HOLD
BIT 3
MIN
BIT1
0
BIT 6
BIT 5
BIT 4
BIT 0
If Hold field is 1, Hold function is active. Hold function will not influence Digital 3~0
which is related to current measured value.
If MAX field is 1, MAX/MIN is active and LCD panel display max value.
If MIN field is 1, MAX/MIN is active and LCD panel display min value.