ES51985
6000 Count AUTO DMM
The meter always outputs the current input value to the serial port in spite of HOLD
mode. Each block is repeated twice in one conversion cycle. The detailed data format of
each packet is listed above.
4.1 FUNCTUON
This packet indicates the measurement mode of the meter. The following table
summarizes the transmitted code for each mode. Note that the encoding of this packet is
different from the encoding of FC1-FC4 switch.
Code
Measurement Mode
Voltage
µA Current
mA Current
Auto A current
Manual A Current
Ω
0111011
0111101
0111111
0110000
0111001
0110011
0110101
0110001
0110010
0110100
0111110
0111100
0111000
0111010
Continuity
Diode
Frequency
1*Temperature
ADP0
ADP1
ADP2
ADP3
Note: 1*.The judge bit in the Status packet determines whether the unit is Celcius or
Fahrenheit.
4.2 RANGE
This packet indicates the full scale range of the meter. When the meter operates in
continuity mode, diode mode, or current (A) mode, this packet is always 0110000 since
the full scale range in these modes are fixed. The following table lists the code for each
range in each measurement mode.
Code
V
mA
µA
Auto A
6.000 A
Frequency
6.000KHz
Ω
0110000
0110001
0110010
0110011
6.000V
60.00V
600.0V
6000V
60.00mA
600.0µA
600.0Ω
600.0mA
6000µA
60.00 A 6.000KΩ 60.00KHz
60.00KΩ 600.0KHz
600.0KΩ 6.000MHz
6.000MΩ 60.00MHz
60.00MΩ
0110100 600.0mV
0110101
0110110
13
07/01/02