CY7B991V
3.3V RoboClock
®
Capacitance
Tested initially and after any design or process changes that may affect these parameters.
Parameter
C
IN
Description
Input Capacitance
Test Conditions
T
A
= 25°C, f = 1 MHz, V
CC
= 3.3V
Max
10
Unit
pF
AC Test Loads and Waveforms
Figure 9. Test Loads and Waveforms
V
CC
R1
C
L
R1=100
R2=100
C
L
= 30 pF
(Includes fixture and probe capacitance)
2.0V
V
th
=1.5V
0.8V
0.0V
≤ 1
ns
3.0V
2.0V
V
th
=1.5V
0.8V
≤
1 ns
R2
TTL AC Test Load
TTL Input Test Waveform
Note
10. Applies to REF and FB inputs only. Tested initially and after any design or process changes that may affect these parameters.
Document Number: 38-07141 Rev. *C