CYW20702
9.3 Electrostatic Discharge
Table 30. Electrostatic Discharge Classification – Human Body Model (ESD – HBM)a
Title
Description
CLASS 0
< 250V
CLASS 1A
CLASS 1B
CLASS 1C
CLASS 2
250V to < 500V
500V to < 1000V
1000V to < 2000V
2000V to < 4000V
4000V to < 8000V
≥ 8000V
CLASS 3A
CLASS 3B
Procedures (HBM)
For every pin, a positive and negative pulse is applied between (1) the pin and ground, (2)
the pin and VCC, and (3) the pin and all other pins tied together.
Test
Electrostatic Discharge (ESD)
Conditions
Purpose
Failure
Human Body Model (HBM) JESD22-A114
To establish the ESD sensitivity.
A failure is any device that fails to meet data sheet electrical requirements after ESD testing.
Goal is >1000V on all I/O Pins (HBM)
Pass/Fail
a. JESD22-A114 is used as reference.
Table 31. Electrostatic Discharge – Machine Model (ESD – MM)a
Title
Description
CLASS A
≤ 200V
CLASS B
> 200V to ≤ 400V
> 400V
CLASS C
Procedures (MM)
Each sample is stressed at one voltage level using 1 positive and 1 negative pulse with a
minimum of 0.5 second between pulses per pin for all pin combinations.
Test
Electrostatic Discharge – Charged-Device Model (ESD - MM)
Machine Model (MM) JESD22-A115
Conditions
Purpose
Failure
To establish the ESD sensitivity.
A failure is any device that fails to meet data sheet electrical requirements after ESD testing.
a. JESD22-A115, latest revision, is used as reference.
Document Number: 002-14773 Rev. *L
Page 49 of 55