ACM100  
The Max Q field specifies the Q value for gray level zero. This forms the starting point for the Q function.  
Note: if the Min_Q value is set to be higher than the Max_Q value, the result will be a flat threshold at  
the Min_Q value.  
[11:0] Max_Q:  
0x04 Gain/Gamma Control  
Bit Definition  
15  
0
14  
0
13  
0
12  
0
11  
1
10  
0
9
1
8
1
7
1
6
1
5
0
4
0
3
0
2
1
1
1
0
0
Reserved  
GAMMA_SKIP  
MAX_GAMMA  
GAMMA  
GAMMA_EN  
The Gain/Gamma Control register is used to specify parameters that affect the gamma control of the camera as well as the digital  
gain. The bits are defined as follows:  
[15] Reserved:  
This bit is reserved for future use and should not be set. To ensure compatibility with future releases,  
we recommend using a read/modify/write operation to preserve the status of this bit.  
This field specifies the frequency at which gamma may be updated by the automatic control algorithm  
(when enabled.) The default is set to 2 to account for a one frame latency between the calculation  
of a new value and its effect. Lower values may result in an overshoot in the response to a step  
change in image lighting.  
[14:11]GAMMA_SKIP:  
These bits define the maximum gamma code that will be available to the algorithm controlling the  
dynamic range of the sensor. Changes to this parameter will take affect on the next full frame of video.  
[10:6]MAX_GAMMA:  
[5:1] GAMMA:  
These bits specify the value of gamma to be used when user gamma is enabled. Increasing values  
of gamma represent increasing amounts of signal compression – resulting in increased dynamic  
range. Values of 3 and below are linear and the maximum value of 31 represents the maximum  
dynamic range of the sensor. Changes to this field take affect immediately – even in the middle of a  
frame. This may result in a frame with the top and bottom portions of the image being taken with  
different gamma settings.  
[0] GAMMA_EN:  
Writing a ‘1’ to this bit will enable the use of the gamma value specified in the GAMMA field of this  
register to be used in place of the value calculated by the Autobrite algorithm. This may result in a  
frame with the top and bottom portions of the image being taken with different gamma settings  
0x05 Merge Bins Control 2  
Bit Definition  
15  
14  
0
13  
1
12  
1
11  
0
10  
0
9
0
8
0
7
0
6
0
5
0
4
1
3
0
2
0
1
0
0
0
0
Reserved  
User_Curve_En Draw_Enable  
Min_Q  
The Merge Bins Control register is used to enable and control the behavior of the merge bins contrast enhancement algorithm.  
The merge bins algorithm can be controlled by specifying a Q function that indicates how strongly gray levels should be affected  
by the algorithm. The Q function can be specified in one of several methods as shown in Figure 13.  
Document Number: 001-05325 Rev. **  
Page 11 of 20