欢迎访问ic37.com |
会员登录 免费注册
发布采购

EZE480D18 参数 Datasheet PDF下载

EZE480D18图片预览
型号: EZE480D18
PDF下载: 下载PDF文件 查看货源
内容描述: 全球专家固态继电器技术 [THE GLOBAL EXPERT IN SOLID STATE RELAY TECHNOLOGY]
分类和应用: 继电器固态继电器
文件页数/大小: 20 页 / 1264 K
品牌: CRYDOM [ CRYDOM INC., ]
 浏览型号EZE480D18的Datasheet PDF文件第5页浏览型号EZE480D18的Datasheet PDF文件第6页浏览型号EZE480D18的Datasheet PDF文件第7页浏览型号EZE480D18的Datasheet PDF文件第8页浏览型号EZE480D18的Datasheet PDF文件第10页浏览型号EZE480D18的Datasheet PDF文件第11页浏览型号EZE480D18的Datasheet PDF文件第12页浏览型号EZE480D18的Datasheet PDF文件第13页  
Panel Mount Solid State Relays - AC Output  
CWD, CWA  
H12  
10-125Amp  
25-125Amp  
120/240/480/600 Vac  
480/600 Vac  
SCR AC Switch Output  
Integrated IP20 Fingerproof Cover  
EMC Compliant Design  
SCR AC Switch Output  
1200 Volt Blocking  
The CW series offers a SCR AC switch output featuring low off-state leakage (1mA,  
snubberless), zero cross or random turn-on (-10) switching and a wide operating  
range (28-280Vrms) for optimum performance at 120V ac and 240Vac line voltages.  
High thermal ratings with reduced power dissipation result in reduced heat sink  
requirements for optimum performance. Additional features include; integrated,  
High voltage relays use IC driven circuits for switching loads up to 660 VAC. All  
models come with 1200 Volts blocking standard. Types CA, CD and WD are  
snubberless and feature low off-state leakage. UL 508A SCCR Approved, consult  
Crydom for actual ratings.  
Line  
Load  
Control Control Must  
Surge  
removable finger-proof cover, LED status indication and user-friendly connectors. UL 508A  
SCCR Approved, consult Crydom for actual ratings.  
Voltage  
Range  
Vrms  
Current Voltage Current Release Current  
Range  
Arms  
Range  
@ 5Vdc Voltage 1-Cycle  
Vdc  
mA  
Vdc  
Apk  
Line  
Load  
Control  
Control  
Must  
Release Current  
@ 12Vdc Voltage 1-Cycle  
Surge  
H12WD4825 48-660 .15-25 4-32  
H12WD4850 48-660 .15-50 4-32  
H12WD4875 48-660 .15-75 4-32  
H12WD4890 48-660 .15-90 4-32  
H12WD48125 48-660 .15-125 4-32  
15  
15  
15  
15  
15  
1.0  
1.0  
1.0  
1.0  
1.0  
250  
UL, VDE  
UL, CSA, VDE  
VDE  
UL, CSA, VDE  
UL, cUL  
Voltage Current  
Voltage Current  
Range  
Vrms  
Range  
Arms  
Range  
Vdc  
3-32  
3-32  
3-32  
3-32  
625  
mA  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
Vdc  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
Apk  
400  
1000  
1200  
1750  
CWD2410 24-280 .15-10  
CWD2425 24-280 .15-25  
CWD2450 24-280 .15-50  
CWD2490 24-280 .25-90  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
UL, cUL  
600  
850  
H12D4825  
H12D4850  
H12D4875  
H12D4890  
48-530 .15-25 4-32  
48-530 .15-50 4-32  
48-530 .15-75 4-32  
48-530 .15-90 4-32  
15  
15  
15  
15  
1.0  
1.0  
1.0  
1.0  
250  
UL, cUL, VDE  
UL, CSA, VDE  
VDE  
1350  
2000  
400  
625  
CWD24125 24-280 .25-125 3-32  
1000  
1200  
CWD4810 48-660 .15-10  
CWD4825 48-660 .15-25  
CWD4850 48-660 .15-50  
CWD4890 48-660 .25-90  
4-32  
4-32  
4-32  
4-32  
UL, CSA, VDE  
600  
850  
1350  
2000  
H12CD4825 48-660 .15-25 4-15  
H12CD4850 48-660 .15-50 4-15  
H12CD4890 48-660 .15-90 4-15  
15  
15  
15  
1.0  
1.0  
1.0  
250  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
625  
1200  
CWD48125 48-660 .25-125 4-32  
Line  
Load  
Control Control Must  
Surge  
Voltage  
Range  
Vrms  
Current Voltage Current Release Current  
Line  
Load  
Control  
Control  
Must  
Surge  
Range  
Arms  
Range  
@120Vrms Voltage 1-Cycle  
Voltage Current  
Voltage Current  
Release Current  
Vrms  
mA  
Vrms  
Apk  
Range  
Vrms  
Range  
Arms  
Range  
Vrms  
90-280 6.0  
90-280 6.0  
90-280 6.0  
90-280 6.0  
@120Vrms Voltage 1-Cycle  
mA  
Vrms  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
Apk  
400  
600  
850  
1350  
2000  
400  
600  
850  
H12CA4825 48-660 .15-25 90-140 15  
H12CA4850 48-660 .15-50 90-140 15  
H12CA4890 48-660 .15-90 90-140 15  
10.0  
10.0  
10.0  
250  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
CWA2410 24-280 .15-10  
CWA2425 24-280 .15-25  
CWA2450 24-280 .15-50  
CWA2490 24-280 .25-90  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
UL, cUL  
625  
1200  
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec  
Random turn-on, phase controllable (-10 suffix)  
CWA24125 24-280 .25-125 90-280 6.0  
CWA4810 48-660 .15-10  
CWA4825 48-660 .15-25  
CWA4850 48-660 .15-50  
CWA4890 48-660 .25-90  
90-280 6.0  
90-280 6.0  
90-280 6.0  
90-280 6.0  
HD, HA  
12-125Amp  
1350  
2000  
CWA48125 48-660 .25-125 90-280 6.0  
480Vac  
Operating Temperature Range: -40˚C to 80˚C , isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec  
24 Vac input versions available (E suffix)  
Zero Voltage or Random Turn-on  
Ultra Low Control Current  
SMR, SMR-6  
25-90Amp  
Crydom's HD (DC control) and HA (AC control) relays incorporate the same  
proven technologies as our Series 1. All models come with 1200 volts blocking as  
standard and are available in either zero-cross or random turn-on and phase  
controllable (-10) switching versions.  
120/240/480 Vac  
SCR AC Switch Output  
Versatile System Monitoring SSR  
LED Status Indicators, Alarm Output  
Line  
Load  
Control  
Control  
Must  
Surge  
Voltage Current  
Voltage Current  
Release Current  
Range  
Vrms  
Range  
Arms  
Range  
Vdc  
@ 5Vdc Voltage 1-Cycle  
mA  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
Vdc  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
Apk  
The SMR system monitoring SSR’s offer a wide range of built-in fault condition  
alarms to the end-user. Loss of voltage, open circuit load, relay damage and loss  
of DC supply are constantly monitored. LED status indicators complete the  
package for early detection of equipment problems. SMR-6 models offer the user  
the capability to configure the relay with either inverting or non-inverting control  
and alarm. The alarm circuit can sink or source up to 100mA.  
HD4812  
HD4825  
HD4850  
HD4875  
HD4890  
HD48110  
HD48125  
48-530 .04-12  
48-530 .04-25  
48-530 .04-50  
48-530 .04-75  
48-530 .04-90  
48-530 .15-110 3-32  
48-530 .15-125 3-32  
3-32  
3-32  
3-32  
3-32  
3-32  
140 UL, CSA, VDE  
250 UL, CSA, VDE  
625 UL, CSA, VDE  
1000 UL, CSA, VDE  
1200 UL, CSA, VDE  
1500 UL, cUL  
1750 UL, cUL  
Line  
Load  
Control Control Alarm  
Voltage Current Voltage Current Output  
Surge  
Current  
1-Cycle  
Line  
Load  
Control  
Control  
Must  
Surge  
Range  
Vrms  
Range  
Arms  
Range  
@ 12Vdc Current  
mA  
6
6
6
Voltage Current  
Voltage Current  
Release Current  
Vdc  
mA (max.) Apk  
Range  
Vrms  
Range  
Arms  
Range  
Vrms  
@120Vrms Voltage 1-Cycle  
mA  
SMR2425  
SMR2450  
SMR2490  
60-280 .04-25 8-32  
60-280 .04-50 8-32  
60-280 .04-90 8-32  
100  
100  
100  
100  
100  
100  
100  
100  
100  
250  
625  
UL, CSA, VDE  
UL, CSA, VDE  
Vrms  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
10.0  
Apk  
HA4812  
HA4825  
HA4850  
HA4875  
HA4890  
HA48110  
HA48125  
48-530 .04-12  
48-530 .04-25  
48-530 .04-50  
48-530 .04-75  
48-530 .04-90  
48-530 .15-110 90-280 2.0  
48-530 .15-125 90-280 2.0  
90-280 2.0  
90-280 2.0  
90-280 2.0  
90-280 2.0  
90-280 2.0  
140 UL, CSA, VDE  
250 UL, CSA, VDE  
625 UL, CSA, VDE  
1000 UL, CSA, VDE  
1200 UL, CSA, VDE  
1500 UL, cUL  
1200 UL, CSA, VDE  
SMR2425-6 60-280 .04-25 8-32  
SMR2450-6 60-280 .04-50 8-32  
SMR2490-6 60-280 .04-90 8-32  
6
6
6
250  
625  
120  
250  
625  
UL, CSA, VDE  
UL, CSA, VDE  
UL, CSA, VDE  
SMR4825-6 96-530 .04-25 8-32  
SMR4850-6 96-530 .04-50 8-32  
SMR4890-6 96-530 .04-90 8-32  
6
6
6
CSA, VDE  
CSA, VDE  
1750 UL, cUL  
1200 CSA, VDE  
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec  
24 Vac input versions available (E suffix)  
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec  
Other Crydom products and competitive part number cross-reference available at: www.crydom.com  
9
 复制成功!