Panel Mount Solid State Relays - AC Output
EZ
Series 1
5-18Amp
10-125Amp
120/240/480 Vac
120/240 Vac
SCR AC Switch Output
Low Profile - Quick Connect Terminals
24V Control Available (EZE)
SCR AC Switch Output
Zero Voltage or Random Turn-On
The Series EZ is a SPST-NO AC output relays offer a low profile package and is
the preferred choice for replacement of Electro-mechanical relays. Random Turn-
On models (R suffix) are available.
Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays
deliver proven reliability in the most demanding applications. Relay output
consists of an SCR AC switch and is available in either AC or DC (coil) control.
Options include; zero-cross, random turn-on, phase controllable (add “-10”
suffix); normally closed (Form B) version (add “-B” suffix); 24 Vac control models
(add “E” suffix). UL 508A SCCR Approved, consult Crydom for actual ratings.
Line
Load
Control
Control
Must
Release Current
@5/24Vdc Voltage 1-Cycle
Surge
Voltage Current
Voltage Current
Range
Vrms
Range
Arms
Range
Vdc
mA
13
15
15
15
15
Vdc
1.0
1.0
1.0
1.0
1.0
Apk
EZ240D5
24-280 .15-5
4-15
3-15
3-15
15-32
15-32
40
UL, cUL
D12, D24
EZ240D12 24-280 .15-12
EZ240D18 24-280 .15-18
EZE240D12 24-280 .15-12
EZE240D18 24-280 .15-18
150
200
150
200
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
Line
Load
Control
Control
Must
Release Current
@ 5Vdc Voltage 1-Cycle
Surge
Voltage Current
Range
Vrms
Voltage Current
Range
Arms
Range
Vdc
mA
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
Vdc
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Apk
D1210
D1225
D1240
D2410
D2425
D2450
D2475
D2490
D24110
D24125
24-140 .04-10
24-140 .04-25
24-140 .04-40
24-280 .04-10
24-280 .04-25
24-280 .04-50
24-280 .04-75
24-280 .04-90
3-32
3-32
3-32
3-32
3-32
3-32
3-32
3-32
120
250
625
120
250
625
1000
1200
1500
1750
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, cUL
EZ480D12 48-660 .15-12
EZ480D18 48-660 .15-18
EZE480D12 48-660 .15-12
EZE480D18 48-660 .15-18
4-15
4-15
15-32
15-32
15
15
15
15
1.0
1.0
1.0
1.0
150
200
150
200
UL, CSA
UL, CSA
UL, CSA
UL, CSA
Line
Load
Control
Control
Must
Surge
Voltage Current
Voltage Current @ Release Current
Range
Vrms
Range
Arms
Range
Vrms
120/24Vrms Voltage 1-Cycle
mA
Vrms
10.0
10.0
2.0
Apk
150
200
150
200
24-280 .15-110 3-32
24-280 .15-125 3-32
EZ240A12 24-280 .15-12
EZ240A18 24-280 .15-18
EZE240A12 24-280 .15-12
EZE240A18 24-280 .15-18
90-140 10
90-140 10
18-36
18-36
UL, CSA
UL, CSA
UL, CSA
UL, CSA
UL, cUL
10
10
A12, A24
2.0
Line
Load
Control
Control
Must
Surge
Voltage Current
Range
Vrms
Voltage Current@ Release Current
EZ480A12 48-660 .15-12
EZ480A18 48-660 .15-18
EZE480A12 48-660 .15-12
EZE480A18 48-660 .15-18
90-140 10
90-140 10
10.0
10.0
2.0
150
200
150
200
UL, CSA
UL, CSA
UL, CSA
UL, CSA
Range
Arms
Range
Vrms
120Vrms
mA
Voltage 1-Cycle
Vrms
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
Apk
18-36
18-36
10
10
A1210
A1225
A1240
A2410
A2425
A2450
A2475
A2490
A24110
A24125
24-140 .04-10
24-140 .04-25
24-140 .04-40
24-280 .04-10
24-280 .04-25
24-280 .04-50
24-280 .04-75
24-280 .04-90
90-280 2.0
90-280 2.0
90-280 2.0
90-280 2.0
90-280 2.0
90-280 2.0
90-280 2.0
90-280 2.0
120
250
625
120
250
625
1000
1200
1500
1750
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, cUL
2.0
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms
NTD, NTA
5-25Amp
120/240 Vac
24-280 .15-110 90-280 2.0
24-280 .15-125 90-280 2.0
Zero Cross or Random Turn-On (-10)
UL, cUL
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec
CSW
The NT products are available with either DC control (NTD) or AC control (NTA)
with a wide output range (24-280 Vrms).
10-90Amp
120/240 Vac
Low Leakage
SCR AC Switch Output
Line
Load
Control
Control
Must
Release Current
Voltage 1-Cycle
Vdc
1.0
1.0
1.0
Surge
Voltage Current
Voltage Current
Range
Vrms
Range
Arms
Range
Vdc
@5Vdc
mA
Apk
NTD2405
NTD2410
NTD2425
24-280 .15-5
24-280 .15-10
24-280 .15-25
4-15
3-32
3-32
13
10
10
40
120
250
CSA, CSAus
UL, CSA
UL, CSA
The Series CSW has an SCR AC switch output featuring low off-state leakage
(1mA, snubberless), zero-voltage switching and a broadened operating range (24-
280Vrms). This wide range permits optimum performance at both 120Vac and
240Vac line voltages.
Line
Load
Control
Control
Must
Surge
Voltage Current
Voltage Current @ Release Current
Range
Vrms
Range
Arms
Range
Vrms
120Vrms Voltage 1-Cycle
mA
Vrms
Apk
120
250
Line
Load
Control
Voltage Current
Range
Vdc
Control
Must
Release Current
@ 5Vdc Voltage 1-Cycle
Surge
NTA2410
NTA2425
24-280 .15-10
24-280 .15-25
90-140 10
90-140 10
10
10
UL, CSA
UL, CSA
Voltage Current
Range
Vrms
Range
Arms
mA
13
13
13
13
13
Vdc
1.0
1.0
1.0
1.0
1.0
Apk
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 3750 Vrms
Random turn-on, phase controllable (-10 suffix)
CSW2410 24-280 .15-10
CSW2425 24-280 .15-25
CSW2450 24-280 .15-50
CSW2475 24-280 .25-75
CSW2490 24-280 .25-90
3-32
3-32
3-32
3-32
3-32
120
250
625
1000
1200
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms Minimum Off-State dv/dt 500V/μsec
Random turn-on, phase controllable (-10 suffix)
Americas +1 (877) 502 5500 sales@crydom.com
Europe +44 (0) 1202 606030 sales-europe@crydom.com
Questions? Call or e-mail
8