Panel Mount Solid State Relays - AC Output
HD60, HA60
CMD, CMA
25-125Amp
25-125Amp
120/240/480/600 Vac
SCR AC Switch Output
Zero Cross or Random Turn-on
600 Vac
Zero Voltage or Random Turn-on
Ultra Low Control Current
These Propack SPST-NO solid state relays offer box clamp connections for safety
and ease-of-use. The on-board LED provides visible status indication. Also
available with DIN rail mount and integral heat sink, (see CMR products on page 14).
Model choices include zero-voltage or random turn-on (phase controllable)
switching (add suffix -10).
Crydom's HD60 (DC control) and HA60 (AC control) relays incorporate the same
proven technologies as the HD/HA products with up to 660 Vac load voltage
range, preferred choice in Canada. All models come with 1200 volts blocking as
standard and are available in either zero-cross or random turn-on and phase
controllable (-10) switching versions.
Line
Load
Control
Control
Must
Surge
Line
Load
Control
Control
Must
Surge
Voltage Current
Voltage Current
Release Current
Voltage Current
Voltage Current
Release Current
Range
Vrms
Range
Arms
Range
Vdc
@ 5Vdc Voltage 1-Cycle
mA
Range
Vrms
Range
Arms
Range
Vdc
@ 5Vdc Voltage 1-Cycle
Vdc
Apk
mA
17
17
17
17
17
17
Vdc
1.0
1.0
1.0
1.0
1.0
1.0
Apk
CMD2425 24-280 .15-25
CMD2450 24-280 .15-50
CMD2475 24-280 .25-75
CMD2490 24-280 .25-90
CMD24110 24-280 .25-110 3-32
CMD24125 24-280 .25-125 3-32
3-32
3-32
3-32
3-32
250
625
1000
1200
1500
1750
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA
HD6025
HD6050
HD6090
HD60125
48-660 .04-25
48-660 .04-50
48-660 .04-90
3-32
3-32
3-32
2.0
2.0
2.0
2.0
1.0
1.0
1.0
1.0
250
625
1200
1750
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA
48-660 .15-125 3-32
Line
Load
Control
Voltage Current
Range
Vrms
Control
Must
Release Current
Surge
UL, CSA
Voltage Current
CMD4825 48-530 .15-25
CMD4850 48-530 .15-50
CMD4875 48-530 .25-75
CMD4890 48-530 .25-90
CMD48110 48-530 .25-110 4-32
CMD48125 48-530 .25-125 4-32
4-32
4-32
4-32
4-32
14
14
14
14
14
14
1.0
1.0
1.0
1.0
1.0
1.0
250
625
1000
1200
1500
1750
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA
Range
Vrms
Range
Arms
@120Vrms Voltage 1-Cycle
mA
Vrms
Apk
HA6025
HA6050
HA6090
HA60125
48-660 .04-25
48-660 .04-50
48-660 .04-90
90-280 2.0
90-280 2.0
90-280 2.0
10.0
10.0
10.0
10.0
250
625
1200
1750
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA
UL, CSA
48-660 .15-125 90-280 2.0
CMD6025 48-660 .15-25
CMD6050 48-660 .15-50
CMD6075 48-660 .25-75
CMD6090 48-660 .25-90
CMD60110 48-660 .25-110 4-32
CMD60125 48-660 .25-125 4-32
4-32
4-32
4-32
4-32
14
14
14
14
14
14
1.0
1.0
1.0
1.0
1.0
1.0
250
625
1000
1200
1500
1750
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec
24 Vac input versions available (E suffix)
PRG
UL, CSA
150Amp
120/240/480 Vac
Line
Load
Control
Voltage Current
Range
Vrms
Control
Must
Release Current
Surge
SCR AC Switch Output
High Steady-State Current
Internal Snubber
Voltage Current
Range
Vrms
Range
Arms
@120Vrms Voltage 1-Cycle
mA
Vrms
Apk
CMA2425 24-280 .15-25
CMA2450 24-280 .15-50
CMA2475 24-280 .25-75
CMA2490 24-280 .25-90
CMA24110 24-280 .25-110 90-140 15
CMA24125 24-280 .25-125 90-140 15
90-140 15
90-140 15
90-140 15
90-140 15
10
10
10
10
10
10
250
625
1000
1200
1500
1750
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA
Designed for the most demanding application, the PRG SPST-NO Solid State
Relays offer an exceptionally high (150 Arms current rating). They are designed
for a wide range of applications including; high-intensity incandescent lamp
dimming, motor speed control, reversing and switching, heater or pump controls
and more.
UL, CSA
CMA4825 48-530 .15-25
CMA4850 48-530 .15-50
CMA4875 48-530 .25-75
CMA4890 48-530 .25-90
CMA48110 48-530 .25-110 90-140 15
CMA48125 48-530 .25-125 90-140 15
90-140 15
90-140 15
90-140 15
90-140 15
10
10
10
10
10
10
250
625
1000
1200
1500
1750
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA
Line
Load
Control Control
Must
Release Current
Voltage 1-Cycle
Vdc
1.0
1.0
1.0
1.0
Surge
Voltage Current Voltage Current
Range
Vrms
Range
Arms
Range
Vdc
@ 5Vdc
mA
Apk
PRGD24150
PRGD24150-10 24-280 .15-150 3-15
PRGD48150 48-530 .15-150 4-15
PRGD48150-10 48-530 .15-150 4-15
24-280 .15-150 3-15
15
15
15
15
1750
1750
1750
1750
UL, CSA
CMA6025 48-660 .15-25
CMA6050 48-660 .15-50
CMA6075 48-660 .25-75
CMA6090 48-660 .25-90
CMA60110 48-660 .25-110 90-140 15
CMA60125 48-660 .25-125 90-140 15
90-140 15
90-140 15
90-140 15
90-140 15
10
10
10
10
10
10
250
625
1000
1200
1500
1750
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA, VDE
UL, CSA
Line
Load
Control Control
Must
Surge
Voltage Current Voltage Current
Release Current
UL, CSA
Range
Vrms
Range
Arms
Range
@ 120Vrms Voltage 1-Cycle
mA
Vrms
Vrms
Apk
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec
24 Vac input versions available (E suffix)
PRGA24150
PRGA24150-10 24-280 .15-150 90-140 10
PRGA48150 48-530 .15-150 90-140 10
24-280 .15-150 90-140 10
10
10
10
10
1750
1750
1750
1750
PRGA48150-10 48-530 .15-150 90-140 10
-10 suffix denotes random turn-on.
Operating Temperature Range: -30˚C to 80˚C Isolation Voltage: 4000 Vrms
Americas +1 (877) 502 5500 sales@crydom.com
Europe +44 (0) 1202 606030 sales-europe@crydom.com
Questions? Call or e-mail
10