PCB Mount Solid State Relays - AC Output
ASO
D2W
2-3.5Amp
120/240 Vac
AC SIP
1.5-2Amp
120/240 Vac
AC Mini-SIP
DC Control, SCR AC Switch Output
US Patent No. 5,134,094
Triac Output
The D2W Series features an epoxy-coated package that provides exceptional
environmental protection. Pinouts are compatible with Series 6 and OAC type I/O
modules.
Crydom’s ASO solid state relays are SPST-NO miniature SIP packages rated at
1.5A/2.0A. They are designed for switching highly inductive, low current loads
such as solenoids. Typical applications include: pumps, gaming, vending
machines, security systems, medical equipment and appliances.
Line
Load
Control
Control
Must
Surge
Voltage Current
Voltage Current
Release Current
Range
Range
Range
@ 5Vdc Voltage 1-Cycle
Line
Load
Control
Control
Must
Surge
Vrms
Arms
Vdc
mA
Vdc
Apk
Voltage Current
Voltage Current
Release Current
D2W202F 24-280 .06-2.0 3-32
D2W203F 24-280 .06-3.0 3-32
D2W203F-11 24-280 .06-3.5 3-32
3
3
3
1.0
1.0
1.0
28
70
80
UL, CSA
UL, CSA
UL, CSA
Range
Vrms
Range
Arms
Range
Vdc
@ 5Vdc Voltage 1-Cycle
mA
Vdc
Apk
ASO241
ASO241R* 12-280 .025-1.5 4-10
ASO242 12-280 .06-2.0 4-10
12-280 .025-1.5 4-10
15
15
15
15
1.0
1.0
1.0
1.0
40
40
120
120
UL, CSA
UL, CSA
UL, CSA
UL, CSA
Operating Temperature Range: -30˚C to 80˚C Isolation Voltage: 4000 Vrms
UPD
ASO242R* 12-280 .06-2.0 4-10
15-25 Amp
120/240Vac
* R suffix denotes random turn-on.
Operating Temperature Range: -30˚C to 80˚C Isolation Voltage: 2500 Vrms
Metal Baseplate
High Surge Rating
Zero Cross or Random Turn-On
LC241, LC242
1.5 - 2.0 A
120/240 Vac
AC Mini-SIP
DC Control
Crydom's UPD series solid-state relays are an ideal solution for high-power
switching applications with limited panel space. Single phase, dual output, or
three phase versions are available with either PCB or quick-connect* terminals,
making the UPD series the perfect long-life alternative to many
electromechanical relays.
The LC241/ LC242 offer the popular ASO circuit in cost effective package.
Crydom’s propretary Triac circuitry makes snubbless operation possible in most
applications.
Line
Load
Control Control
Must
Surge
Voltage Current Voltage Current** Release Current
Range Range
Vrms Arms
Range
V DC
3-15
3-15
3-15
3-15
@12Vdc Voltage 1-Cycle
mA
10
10
10
10
V DC
1.0
Apk
120
Line
Load
Control
Control
Must
Release Current
@ 5Vdc Voltage 1-Cycle
Surge
UPD2415
UPD2415-10 24-280 .15-15
UPD2425 24-280 .15-25
UPD2425-10 24-280 .15-25
24-280 .15-15
Voltage Current
Voltage Current
1.0
120
Range
Range
Range
1.0
250
Vrms
Arms
Vdc
mA
15
15
15
15
Vdc
1.0
1.0
1.0
1.0
Apk
1.0
250
LC241
12-280 .025-1.5 4-10
12-280 .025-1.5 4-10
12-280 .025-2.0 4-10
12-280 .025-2.0 4-10
80
80
100
100
UL, CSA
UL, CSA
UL
Line
Load
Control Control
Must
Surge
LC241R*
LC242
Voltage Current Voltage Current
Release Current
Range Range
Range
V DC
3-15
3-15
3-15
3-15
@12Vdc Voltage 1-Cycle
mA
14/36
14/36
14/36
14/36
Dual
Vrms Arms
V DC
Apk
LC242R*
UL
UPD2415D 24-280 .15-15
UPD2415D-10 24-280 .15-15
UPD2425D 24-280 .15-25
UPD2425D-10 24-280 .15-25
1.0
120
*R Suffix denotes random turn-on.
Operating Temperature Range: -40˚C to 80˚C Isolation Voltage: 2500 Vrms
1.0
120
1.0
250
1.0
250
CX241
Line
Load
Control Control
Must
Release Current
Surge
Voltage Current Voltage Current
1.5Amp
Range Range
Range
V DC
4.5-8
4.5-8
@ 5Vdc Voltage 1-Cycle
3Phase
120/240 Vac
Vrms
Arms
mA
14
14
V DC
1.0
1.0
Apk
120
120
UPD2415TP 24-280 .15-15
UPD2415TP-10 24-280 .15-15
* Contact factory for availability.
AC SIP, SCR AC Switch Output
Zero Cross or Random Turn-On
US Patent No. 5,134,094
** Input circuit incorporates active current limiter.
MP
The CX241/R AC relays are SPST-NO solid state relays. Both models offer the ASO
circuit with the popular CX pinout.
3-4Amp
120/240 Vac
Triac AC Output SIP
5, 15 & 24 Volt Logic System Compatible
Line
Load
Control
Control
Must
Surge
Voltage Current
Voltage Current
Release Current
Range
Range
Range
@ 5Vdc Voltage 1-Cycle
Vrms
Arms
Vdc
mA
Vdc
Apk
CX241
CX241R*
12-280 .025-1.5 4-10
12-280 .025-1.5 4-10
15
15
1.0
1.0
40
40
UL, CSA, VDE
UL, CSA, VDE
Available in 3Arms and 4Arms ratings, all are SPST-NO PC-mount relays that provide
greater packaging density and compatibility with pinout of Series 6 and OAC output
modules. For DC output see page 7 for the MPDCD3.
*R Suffix denotes random turn-on.
Operating Temperature Range: -30˚C to 80˚C Isolation Voltage: 4000 Vrms
Line
Load
Control
Control
Must
Surge
MCX241
Voltage Current
Voltage Current
Release Current
Range
Vrms
Range
Arms
Range
Vdc
@ 5Vdc Voltage 1-Cycle
mA
The MCX241/MCX241R offer the same specifications
and performance as the the CX241, the only differ-
ence is the MP style package. Add a “M” prefix to
the above part numbers for this option. Pinouts are
compatible with Series 6 and OAC type I/O modules.
MCX241 models are UL, CSA and VDE approved.
Vdc
Apk
MP240D2
MP120D3
MP240D3
MP120D4
MP240D4
24-280
12-140
24-280
12-140
24-280
.02-2.0
.02-3.0
.02-3.0
.02-4.0
.02-4.0
3-32
3-32
3-32
3-32
3-32
2.6
2.6
2.6
2.6
2.6
1.0
1.0
1.0
1.0
1.0
50
90
UL, CSA, VDE
UL, CSA, VDE
90
130
130
CSA, VDE
Operating Temperature Range: -40˚C to 80˚C Isolation Voltage: 4000 Vrms
Other Crydom products and competitive part number cross-reference available at: www.crydom.com