欢迎访问ic37.com |
会员登录 免费注册
发布采购

RS8953BEPJ 参数 Datasheet PDF下载

RS8953BEPJ图片预览
型号: RS8953BEPJ
PDF下载: 下载PDF文件 查看货源
内容描述: 高比特率数字用户线( HDSL )信道单元 [High-Bit-Rate Digital Subscriber Line (HDSL) channel unit]
分类和应用: 电信集成电路
文件页数/大小: 173 页 / 1229 K
品牌: CONEXANT [ CONEXANT SYSTEMS, INC ]
 浏览型号RS8953BEPJ的Datasheet PDF文件第63页浏览型号RS8953BEPJ的Datasheet PDF文件第64页浏览型号RS8953BEPJ的Datasheet PDF文件第65页浏览型号RS8953BEPJ的Datasheet PDF文件第66页浏览型号RS8953BEPJ的Datasheet PDF文件第68页浏览型号RS8953BEPJ的Datasheet PDF文件第69页浏览型号RS8953BEPJ的Datasheet PDF文件第70页浏览型号RS8953BEPJ的Datasheet PDF文件第71页  
RS8953B/8953SPB  
3.0 Circuit Descriptions  
HDSL Channel Unit  
3.6 PRA Function  
Enabling the CRC4 generator causes CRC4 regeneration of the E1 data  
(RSER). The result is inserted into the data stream in the appropriate location in  
accordance with the CRC4 procedure specified in CCITT recommendation  
G.704.  
If the CRC4 generator is disabled, the following options are available: New  
values are inserted for the CRC4 bits, or you can leave the CRC4 bits untouched.  
If new values are inserted, an external CPU must be used to program the value of  
these bits. To implement this, a simple storage register can be used to insert four  
bits into the data stream. The CRC4 insertion is repeated each E1 frame until  
another value is programmed, or until another mode is selected.  
3.6.2 Definitions of Detection Algorithms  
When transferring data from HDSL or RSER, the following definitions of  
detection algorithms apply:  
Normal operational frames: The algorithm will be in accordance with  
CCITT Recommendation G.706[7]. This condition is indicated by one bit  
in a register.  
Loss of frame alignment: The algorithm will be in accordance with CCITT  
Recommendation G.706[7]. This condition is indicated by one bit in a  
register.  
Code words: Code words consist of four SA6 bits and the A-bit. A new  
code is declared only when the value of the SA6 bits and the A-bit remains  
the same in the last eight frames. The code word is then stored in a 5-bit  
register.  
3.6.3 Inserting Data Transferred from HDSL to RSER  
When transferring data from HDSL to RSER, bits are transferred in the following  
manner:  
Each A-bit and SA4, SA5, SA7, and SA8 bit may be selected as  
transparent or non-transparent. For non-transparent bits, the new value of  
the certain bit is stored in a register and is inserted into the correct location  
of the data stream (RSER).  
The SA6 bits may be transferred either transparently or non-transparently.  
Selecting transparent or non-transparent affects all four SA6 bits. For  
non-transparent transfers, the new value of the bits is stored in a register  
and is inserted into the correct location of the data stream (RSER).  
The FAS bits may be transferred either transparently or non-transparently.  
Selecting transparent or non-transparent affects all the FAS bits. For  
non-transparent bits, the FAS value is inserted into the correct location of  
the data stream (RSER).  
3.6.4 Transferring Data from TSER to HDSL  
When CRC4 monitoring is enabled, data received from TSER is checked for error  
blocks by using the CRC4 procedure, as specified in CCITT recommendation  
G.704[9], subclause 2.3.3. The check result, reflected by the E-bits, is inserted  
into the correct location of the data stream.  
N8953BDSB  
Conexant  
3-35  
 复制成功!