CX28394/28395/28398  
2.0 Circuit Description  
Quad/x16/OctalT1/E1/J1 Framers  
2.2 Receiver  
2.2.2 In-Band Loopback Code Detection  
The in-band loopback code detector circuitry detects receive data with in-band  
codes of configurable value and length. These codes can be used to request  
loopback of terminal equipment signals or other user specified applications. The  
two codes are referred to as loopback-activate and loopback-deactivate, although  
the detectors need not be used only for loopback codes. Generally, any repeating  
1–7 bit pattern can be selected. The loopback application is described in Section  
9.3.1 of ANSI T1.403-1995. The loopback activate code is set in the Loopback  
Activate Code Pattern [LBA; addr 043]. The loopback deactivate code is set in the  
Loopback Deactivate Code Pattern [LBD; addr 044].  
The sequence length for the loopback activate and deactivate codes can be  
programmed for 4, 5, 6, or 7 bits by setting the code length bits of the Receive  
Loopback Code Detector Configuration register [RLB; addr 042]. Shorter codes  
can be programmed by repeating the expected pattern (e.g. 3+3 bit code  
programmed as 6-bit code).  
T1 In-Band Loopback Codes  
Activate 00001  
Deactivate 001  
When a loopback code is detected, the LOOPUP or LOOPDN status bit is set  
in Alarm 2 register [ALM2; addr 048], and the corresponding LOOPUP or  
LOOPDN bit in Alarm 2 Interrupt Status register (ISR6; addr 005] is set. The  
loopback detection interrupt can be enabled using the Alarm 2 Interrupt Enable  
register [IER6; addr 00D]. When enabled, a loop-up or loop-down code detection  
causes the Alarm 2 Interrupt bit [ALARM2] to be set in the Interrupt Request  
register [IRR; addr 003] and generates an interrupt. Since loopbacks are not  
automatically initiated, the processor must intercept and interpret the interrupt  
status condition to determine when it must enable or disable the loopback control  
mechanism (e.g., LLOOP; addr 014).  
2.2.3 Error Counters  
The following Performance Monitoring (PM) counters are available in the RCVR:  
Framing Bit Errors (FERR)  
CRC Errors (CERR)  
Line Code Violations (LCV)  
Far End Block Errors (FEBE)  
All PM count registers are reset on read unless LATCH_CNT is set in the  
Alarm/Error/Counter Latch Configuration register [LATCH; addr 046].  
LATCH_CNT enables the one-second latching of counts coincident with the  
one-second timer interrupt [ISR6; addr 005]. One-second latching of PM counts  
is required if AUTO_PRM responses are enabled. All PM counters can be  
disabled during RLOF, RLOS, and RAIS, using the STOP_CNT bit in the  
LATCH register.  
Note that if STOP_CNT is negated, error monitoring during RLOF conditions  
will detect FERR, CERR, and FEBE according to the last known frame  
alignment.  