3.0 Registers  
CX28394/28395/28398  
3.9 Receiver Registers  
Quad/x16/OctalT1/E1/J1 Framers  
045—Receive Alarm Signal Configuration (RALM)  
Unused bits are reserved and should be written to 0.  
7
6
5
4
3
2
1
0
DIS_LCV  
FS_NFAS  
EXZ_LCV  
YEL_INTEG  
RLOF_INTEG  
RPCM_YEL  
RPCM_AIS  
DIS_LCV  
FS_NFAS  
Disable LCV indication and counting. Primarily used in configurations where receive data is  
unipolar NRZ. If AUTO_PRM is enabled (PRM; addr 0AA) LV is transmitted with a default  
value of 0.  
0 = LCV counting and indication enabled  
1 = LCV counting and indication disabled  
Include FS/NFAS in FERR and FRED—Selects whether Fs bit errors (T1) or NFAS Bit2  
errors (E1) are counted as frame errors [FERR; addr 050, 051]. Further selects whether loss of  
frame alignment [FRED; addr 049] includes Fs or NFAS bit errors as part of the detection  
criteria. Note that the number of Fs bit locations checked also depends on JYEL framer mode.  
0 = FERR and FRED do not include FS/NFAS  
1 = FERR and FRED include FS/NFAS  
EXZ_LCV  
Excess Zeros Included in LCV—Whether line code violation error count [LCV; addr 054,  
055] includes EXZ errors depends on the EXZ_LCV control setting. Depending on RZCS bit  
setting [addr 040], each EXZ is equal to either 8 or 16 consecutive zeros.  
0 = LCV does not include EXZ  
1 = LCV includes EXZ  
YEL_INTEG  
Enable Yellow Alarm Integration—When set, both the receive frame and multiframe yellow  
alarms [RYEL and RMYEL; addr 047] are integrated, as described in Table 3-13 (per the  
selected framer mode). RYEL and RMYEL interrupt status [ISR7; addr 004] are similarly  
affected.  
0 = normal RYEL and RMYEL status  
1 = integrated RYEL and RMYEL status  
Table 3-13. Receive Yellow Alarm Set/Clear Criteria (1 of 2)  
Mode  
Set/Clear Criteria  
Y0  
Set for 4 frames (500 µs) if 2 consecutive NFAS frames each contain TS0 bit 3 = 1. Cleared for 4 frames if 2  
consecutive NFAS frames each contain TS0 bit 3 = 0.  
Y0_INT  
Y16  
Set for 16 multiframes (24 ms) if every NFAS frame contains TS0 bit 3 = 1. Cleared for 16 multiframes if 1 or  
more NFAS frames contain TS0 bit 3 = 0.  
Set for 2 multiframes (4 ms) if frame 0 in 2 consecutive multiframes contains TS16 bit 6 = 1. Cleared for 2  
multiframes if frame 0 in 2 consecutive multiframes contains TS16 bit 6 = 0.  
Y16_INT  
YB2  
Set for 16 multiframes (24 ms) if every frame 0 contains TS16 bit 6 = 1. Cleared for 16 multiframes if at  
least 1 frame 0 contains TS16 bit 6 = 0.  
Set for 1 frame (125 µs) if all 24 time slots contain bit 2 = 0. Cleared for 1 frame if 1 or more time slots  
contain bit 2 = 1.  
YB2_INT  
Set for 192 frames (24 ms) if less than 15 time slots contain bit 2 = 0. Cleared for 192 frames if 15 or more  
time slots contain bit 2 = 1.  
3-42  
Conexant  
100054E  
 