4-Level FSK Modem Data Pump  
Page 19 of 50  
MX929B PRELIMINARY INFORMATION  
RXIN Signal  
for Task 1  
for Task 2  
IRQ Output (IRQEN = '1')  
IRQ Bit of Status Register  
BFREE Bit of Status Register  
Task from µC to Command  
Register  
Task 1  
Task 2  
Data from Block Buffer to µC  
Task 1 data  
Figure 10: Receive Task Overlapping  
Detailed timings for the various tasks are provide in Figure 11 and Figure 12.  
MX929B Modem Tasks:  
B2 B1 B0  
Receive Mode  
Transmit Mode  
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
NULL  
SFP  
RHB  
RILB  
SFS  
NULL  
T24S  
THB  
TIB  
TLB  
T4S  
Search for Frame Preamble  
Read Header Block  
Read Intermediate or Last Block  
Search for Frame Sync  
Read 4 symbols  
Transmit 24 symbols  
Transmit Header Block  
Transmit Intermediate Block  
Transmit Last Block  
Transmit 4 symbols  
R4S  
RSID  
Read Station ID  
TSID  
Transmit Station ID  
RESET Cancel any current action  
RESET Cancel any current action  
4.5.2.7 NULL: No effect  
This is provided so an AQSC or AQLEV command can be initiated without loading a new task.  
4.5.2.8 SFP: Search for Frame Preamble  
This task causes the modem to search the received signal for a valid 24-symbol Frame Preamble, consisting  
of a 24-symbol Frame Sync sequence followed by Station ID Block which has a correct CRC0 checksum.  
The task continues until a valid Frame Preamble has been found.  
The search consists of four stages:  
First the modem will attempt to match the incoming symbols against the Frame Synchronization pattern  
to within the tolerance defined by the FSTOL bits of the Control Register.  
Once a match has been found, the modem will read in the following 'S' symbol, place it in the SVAL bits  
of the Status Register then set the SRDY bit to '1'. (The IRQ bit of the Status Register will also be set to  
'1' at this time if the SSIEN bit of the Mode Register is '1').  
The modem will then read the next 22 symbols as station ID data. They will be decoded and the CRC0  
checked. If this is incorrect, the modem will resume the search, looking for a fresh Frame Sync pattern.  
If the received CRC0 is correct, the following 'S' symbol will be read into the SVAL bits of the Status  
Register and the SRDY, BFREE, and IRQ bits set to '1', the CRCERR bit cleared to '0', and the three  
decoded Station ID bytes placed into the Data Block Buffer.  
Upon detecting that the BFREE bit of the Status Register has gone to '1', the µC should read the three Station  
ID bytes from the Data Block Buffer and then write the next task to the modem's Command Register.  