CPC7582  
switch will remain in the on state no matter the logic  
input until the next zero crossing. These switching  
characteristics will reduce and possibly eliminate  
overall system impulse noise normally associated with  
ringing switches. See application note AN-144, Impulse  
Noise Benefits of Line Card Access Switches. The  
attributes of ringing switch SW4 may make it possible  
to eliminate the need for a zero-cross switching  
scheme. A minimum impedance of 300 Ω in series  
with the ringing generator is recommended.  
and faults are shunted to F  
diode bridge.  
via the SCR or the  
GND  
In order for the SCR to crowbar or foldback, the on  
voltage (see “Protection Circuitry Electrical  
Specifications” on page 10) of the SCR must be less  
negative than the V  
voltage. If the V  
voltage is  
BAT  
BAT  
less negative than the SCR on voltage or if the V  
supply is unable to source the trigger current, the SCR  
will not crowbar.  
BAT  
For power induction or power-cross fault conditions,  
the positive cycle of the transient is clamped to the  
diode drop above ground and the fault current directed  
to ground. The negative cycle of the transient will  
cause the SCR to conduct when the voltage exceeds  
2.6 Power Supplies  
Both a +5 V supply and battery voltage are connected  
to the CPC7582. CPC7582 switch state control is  
powered exclusively by the +5 V supply. As a result,  
the CPC7582BC exhibits extremely low power  
dissipation during both active and idle states.  
the V  
voltage by two to four volts, steering the  
BAT  
current to ground.  
The battery voltage is not used for switch control but  
rather as a supply for the integrated secondary  
protection circuitry. The integrated SCR is designed to  
2.8.2 Current Limiting function  
If a lightning strike transient occurs when the device is  
in the talk state, the current is passed along the line to  
the integrated protection circuitry and limited by the  
dynamic current limit response of the active switches  
during the talk state. During the talk state, when a  
1000V 10x1000 μs pulse (GR-1089-CORE lightning)  
is applied to the line though a properly clamped  
trigger when pin 2 (T ) or pin 15 (R ) drops 2 to  
BAT  
BAT  
4 V below the voltage on pin 16 (V ). This trigger  
BAT  
prevents a fault induced overvoltage event at the T  
BAT  
or R  
nodes.  
BAT  
external protector, the current seen at pins 2 (T  
)
BAT  
2.7 Battery Voltage Monitor  
The CPC7582 also uses the V  
and pin 15 (R ) will be a pulse with a typical  
BAT  
voltage to monitor  
BAT  
magnitude of 2.5 A and a duration of less than 0.5 μs.  
battery voltage. If battery voltage is lost, the CPC7582  
immediately enters the all-off state. It remains in this  
state until the battery voltage is restored. The device  
also enters the all-off state if the system battery  
voltage goes more positive than –10 V, and remains in  
the all-off state until the battery voltage goes more  
negative than –15 V. This battery monitor feature  
draws a small current from the battery (less than 1 μA  
typical) and will add slightly to the device’s overall  
power dissipation.  
If a power-cross fault occurs with the device in the talk  
state, the current is passed though break switches  
SW1 and SW2 on to the integrated protection circuit  
and is limited by the dynamic DC current limit  
response of the two break switches. The DC current  
limit, specified over temperature, is between 80 mA  
and 425 mA, and the circuitry has a negative  
temperature coefficient. As a result, if the device is  
subjected to extended heating due to a power cross  
fault, the limited current measured at pin 3 (T  
) and  
LINE  
pin 14 (R  
) will decrease as the device temperature  
LINE  
2.8 Protection  
increases. If the device temperature rises sufficiently,  
the temperature shutdown mechanism will activate  
and the device will enter the all-off state.  
2.8.1 Diode Bridge/SCR  
The CPC7582 uses a combination of current limited  
break switches, a diode bridge/SCR clamping circuit,  
and a thermal shutdown mechanism to protect the  
SLIC device or other associated circuitry from damage  
during line transient events such as lightning. During a  
positive transient condition, the fault current is  
2.9 Temperature Shutdown  
The thermal shutdown mechanism will activate when  
the device temperature reaches a minimum of 110° C,  
placing the device in the all-off state regardless of  
logic input. During thermal shutdown mode, pin 7  
conducted through the diode bridge to ground via  
F
. Voltage is clamped to a diode drop above  
GND  
(T ) will read 0 V. Normal output of T is +V .  
SD  
SD  
DD  
ground. During a negative transient of 2 to 4 V more  
negative than the voltage at V , the SCR conducts  
BAT  
R05  