欢迎访问ic37.com |
会员登录 免费注册
发布采购

CS5101A-JL16 参数 Datasheet PDF下载

CS5101A-JL16图片预览
型号: CS5101A-JL16
PDF下载: 下载PDF文件 查看货源
内容描述: 16位, 100kHz的/ 20kHz的A / D转换器 [16-Bit, 100kHz/ 20kHz A/D Converters]
分类和应用: 转换器
文件页数/大小: 40 页 / 461 K
品牌: CIRRUS [ CIRRUS LOGIC ]
 浏览型号CS5101A-JL16的Datasheet PDF文件第31页浏览型号CS5101A-JL16的Datasheet PDF文件第32页浏览型号CS5101A-JL16的Datasheet PDF文件第33页浏览型号CS5101A-JL16的Datasheet PDF文件第34页浏览型号CS5101A-JL16的Datasheet PDF文件第36页浏览型号CS5101A-JL16的Datasheet PDF文件第37页浏览型号CS5101A-JL16的Datasheet PDF文件第38页浏览型号CS5101A-JL16的Datasheet PDF文件第39页  
CS5101A CS5102A  
PARAMETER DEFINITIONS  
Linearity Error  
The deviation of a code from a straight line passing through the endpoints of the transfer  
function after zero- and full-scale errors have been accounted for. "Zero-scale" is a point 1/2  
LSB below the first code transition and "full-scale" is a point 1/2 LSB beyond the code  
transition to all ones. The deviation is measured from the middle of each particular code. Units  
in % Full-Scale.  
Differential Linearity  
Minimum resolution for which no missing codes is guaranteed. Units in bits.  
Full Scale Error  
The deviation of the last code transition from the ideal (VREF-3/2 LSB’s). Units in LSB’s.  
Unipolar Offset  
The deviation of the first code transition from the ideal (1/2 LSB above AGND) when in  
unipolar mode (BP/UP low). Units in LSB’s.  
Bipolar Offset  
The deviation of the mid-scale transition (011...111 to 100...000) from the ideal (1/2 LSB below  
AGND) when in bipolar mode (BP/UP high). Units in LSB’s.  
Bipolar Negative Full-Scale Error  
The deviation of the first code transition from the ideal when in bipolar mode (BP/UP high).  
The ideal is defined as lying on a straight line which passes through the final and mid-scale  
code transitions. Units in LSB’s.  
Signal to Peak Harmonic or Noise  
The ratio of the rms value of the signal to the rms value of the next largest spectral component  
below the Nyquist rate (excepting dc). This component is often an aliased harmonic when the  
signal frequency is a significant proportion of the sampling rate. Expressed in decibels.  
Total Harmonic Distortion  
The ratio of the rms sum of all harmonics to the rms value of the signal. Units in percent.  
Signal-to-(Noise + Distortion)  
The ratio of the rms value of the signal to the rms sum of all other spectral components below  
the Nyquist rate (excepting dc), including distortion components. Expressed in decibels.  
Aperture Time  
The time required after the hold command for the sampling switch to open fully. Effectively a  
sampling delay which can be nulled by advancing the sampling signal. Units in nanoseconds.  
Aperture Jitter  
The range of variation in the aperture time. Effectively the "sampling window" which ultimately dic-  
tates the maximum input signal slew rate acceptable for a given accuracy. Units in picoseconds.  
DS45F2  
35  
 复制成功!