DAC_M1 DAC_M0  
Input Sample Rate (Fs)  
4 kHz - 50 kHz  
32 kHz - 48 kHz  
50 kHz - 100 kHz  
100 kHz - 200 kHz  
MODE  
0
0
1
1
0
1
0
1
Single-Speed Mode (without De-emphasis)  
Single-Speed Mode (with De-emphasis)  
Double-Speed Mode  
Quad-Speed Mode  
Table 3. CS42406 Stand Alone DAC Operational Modes  
4.1.2b  
Control Port Mode  
The DAC’s operate in one of three operational modes determined by the FM bits (see section 6.1.4) in  
Control Port mode. Sample rates outside the specified range for each mode are not supported.  
FM1  
FM0  
Input Sample Rate (Fs)  
4 kHz - 50 kHz  
50 kHz - 100 kHz  
100 kHz - 200 kHz  
Reserved  
MODE  
Single-Speed Mode  
Double-Speed Mode  
Quad-Speed Mode  
Reserved  
0
0
1
1
0
1
0
1
Table 4. CS42406 Control Port DAC Operational Modes  
4.2 ADC Serial Port Operation as Either a Clock Master or Slave  
The CS42406 ADC serial port supports operation as either a clock master or slave. As a clock master, the  
ADC_LRCK and ADC_SCLK pins are outputs with the left/right and serial clocks synchronously generated on-chip.  
As a clock slave, the ADC_LRCK and ADC_SCLK pins are inputs and require the left/right and serial clocks to be  
externally generated. The selection of clock master or slave is made via the ADC_Mx pins as shown in Table 5.  
ADC_M1  
ADC_M0  
MODE  
0
0
1
1
0
1
0
1
Clock Master, Single-Speed Mode  
Clock Master, Double-Speed Mode  
Clock Master, Quad-Speed Mode  
Clock Slave, All Speed Modes  
Table 5. CS42406 ADC Serial Port Mode Control  
4.2.1 Operation as a Clock Master  
As a clock master, ADC_LRCK and ADC_SCLK operate as outputs. The left/right and serial clocks are internally  
derived from the master clock with the left/right clock equal to Fs and the serial clock equal to 64x Fs, as shown in  
Figure 34.  