Acknowledge Polling
CAT1320, CAT1321
Read Operations
Disabling of the inputs can be used to take advantage of
the typical write cycle time. Once the stop condition is
issuedtoindicatetheendofthehost’swriteopration, the
CAT1320/21initiatestheinternalwritecycle.ACKpolling
can be initiated immediately. This involves issuing the
start condition followed by the slave address for a write
operation.Ifthedeviceisstillbusywiththewriteoperation,
no ACK will be returned. If a write operation has
completed, an ACK will be returned and the host can
then proceed with the next read or write operation.
The READ operation for the CAT1320/21 is initiated in
the same manner as the write operation with one
exception, that R/W bit is set to one. Three different
READ operations are possible: Immediate/Current
Address READ, Selective/Random READ and
Sequential READ.
Figure 10. Immediate Address Read Timing
S
T
A
R
T
S
T
O
P
BUS ACTIVITY:
MASTER
SLAVE
ADDRESS
SDA LINE
S
P
A
C
K
N
O
DATA
A
C
K
SCL
SDA
8
9
8TH BIT
DATA OUT
NO ACK
STOP