4
C-Series Circuit Breaker – General Specifications
Electrical Tables
Table B: Lists UL Recognized and CSA Accepted configurations and performance capabilities as a Manual Motor Controller.
Notes:
C-SERIES TABLE B: Manual Motor Controllers
1. Requires branch circuit backup with a UL Listed
Type K5 or RK5 fuse rated 15A Minimum and no
Voltage
Frequency
50 / 60
Current Rating
Full Load Amps
0.02 - 50
Horsepower Ratings
Circuit
Configuration
more than 4 times full load amps not to exceed
125A for 50 Amp or less rating and not to exceed
175A for 51 through 100A rating.
Max. Rating
120 1
Phase
Max. HP
1
1
3
1
3
7 ꢀ
3
5
3
5
2. UL Recognized and CSA Certified at 480V refers
to 3 and 4 pole versions used in a 3Ø, WYE
connected circuit or a 2 pole version with 2 poles
breaking 1Ø and backed up with a series fusing as
stated in note 1.
Series,
Shunt &
Relay Switch
Only
0.02 - 20
0.02 - 20
0.02 - 20
0.02 - 20
250 1
50 / 60
277 1
480 2
50 / 60
50 / 60
*
Shunt and Relay Trip - Voltage Coil
Construction not current coils
Table C: Lists UL Recognized, CSA Accepted, VDE and TUV Certified configurations and performance capabilities as a
Component Supplementary Protector.
C-SERIES TABLE C: Component Supplementary Protectors
Voltage
Current Rating
Short Circuit Capacity (Amps)
UL / CSA VDE
TUV
Application
Codes
Circuit
Configuration
Full General
(Inc)
(Icn)
(Inc)
(Icn)
Construction Notes
Max.
Rating
With Without
Backup Backup
Frequency Phase Load Purpose
With Without With Without
Backup Backup Backup Backup
Amps
Amps 1
UL / CSA
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
---
---
---
---
0.10 - 70
71 - 100 71 - 100
1 - 50
0.10 - 50
0.10 - 70
0.10 - 100
0.10 - 90
---
---
---
---
7,500
10,000
5,000
---
---
---
---
5,000 5,000 1,500 TC1,2,OL1,U1
---
80
DC
Agency F, H, J or R
Agency J or R
2P, Agency J or R
---
5,000
---
---
---
---
---
5,000 TC1,2,OL0,U1
5,000 TC1,2,OL1,U1
5,000
125
DC
DC
---
Series
3,000 1,500 3,000 1,500
---
---
3,000 1,500
5,000 2,500
---
250
1
3
3
---
---
5,000
TC1,2,OL1,U1
50 / 60
---
---
Agency J or R
5,000 5,000
Rocker
415
50 / 60
0.10 - 30
---
---
5,000 2
---
---
3,000 1,500 TC1,2,OL1,C1
Handle, Agency F, H, J or R
80
250
80
DC
50 / 60
DC
---
1 & 3
---
7,500
5,000 3,000
7,500 ---
5,000
---
Dual Coil
0.10 - 30
0.10 - 70
1,500
1,500 TC1,2,OL1,U1
3,000
---
---
---
---
---
5,000 5,000 1,500 TC1,2,OL1,U1
---
250
50 / 60
1 & 3 0.10 - 70
5,000 3,000 1,500 3,000 1,500 TC1,2,OL1,U1
3,000 1,500
Shunt
Rocker
415
50 / 60
3
0.10 - 30
---
5,000 2
---
3,000 1,500 TC1,2,OL1,C1
Handle, Agency F, H, J or R
5,000 2,500
Notes:
1.
2.
General Purpose ratings for UL/CSA only.
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less
rating and not to exceed 175 for 51 through 100 Amp rating.
Table D: Lists UL Listed (489), CSA Certified (C22.2 No. 5.1-M) configuration and performance capabilities as a Molded Case
Circuit Breaker.
C-SERIES TABLE D: UL489 Listed Branch Circuit Breakers
Voltage
Current Rating Interrupting Capacity (Amps)
Circuit
Configuration
Construction Notes
Max. Rating Frequency Phase Full Load Amps
Without Backup Fuse
50,000 1
10,000
10,000
10,000
5,000
5,000
10,000
5,000
5,000
10,000 1
5,000
10,000
10,000
Limited to 2 Poles Max from 71 - 100 Amps
0.10 - 100
80
DC
---
2 Poles - Parallel Poles
3 Poles - Parallel Poles
101 - 150
151 - 250
0.10 - 100
0.10 - 50
0.10 - 50
51 - 70
1 - 3 Poles
125
125 / 250
DC
DC
---
---
1 or 2 Poles (2 poles required for 250 Volts)
Series
1 - 3 Poles
120
120 / 240
240
50 / 60
50 / 60
50 / 60
1
1
1
2 or 3 Poles (1 pole of a 3 pole unit is neutral)
0.10 - 50
1 Pole
2 Poles
0.10 - 30
0.10 - 20
0.10 - 20
Notes:
Special catalog
1-2 Poles
277
120
50 / 60
50 / 60
1
1
1
number required.
Consult factory.
---
Dual Coil
0.10 - 30
10,000
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com