Table I – Video Control Operation (Output values for setup = 10 IRE and 75 ohm standard load)
Sync
1
0
0
0
0
0
0
0
Blank
X
1
0
0
0
0
0
0
Ref
White
X
X
1
1
0
0
0
0
Bright
X
X
1
0
0
0
1
1
Data
Input
X
X
X
X
000...
111...
000...
111...
Out – (mA) Out – (V) Out – (IRE)
28.57
20.83
0.00
1.95
19.40
1.95
17.44
0.00
–1.071
–0.781
0.000
–0.073
–0.728
–0.073
–0.654
0.000
–40
0
110
100
7.5
100
17.5
110
Description
Sync Level
Blank Level
Enhanced High Level
Normal High Level
Normal Low Level
Normal High Level
Enhanced Low Level
Enhanced High Level
by the switched current sinks. When FT is tied high, the
control inputs and data are not registered. The analog
output asynchronously tracks the input data and video
controls. Feedthrough itself is asynchronous and usually
used as a DC control.
The controls and data have to be present at the input pins
for a set-up time of t
S
before, and a hold time of t
H
after,
the rising edge of the clock (CONV) in order to be syn-
chronously registered. The set-up and hold times are not
important in the asynchronous mode. The minimum
pulse widths high (t
PWH
) and low (t
PWL
) as well as settling
time become the limiting factors. (See figure 3.)
The video controls produce the output levels needed for
horizontal blanking, frame synchronization, etc., to be
compatible with video system standards as described in
Figure 4 – Video Output Waveform for Standard Load
IRE
110
100
0 mV
–73 mV
Bright
RS-343-A. Table I shows the video control effects on the
analog output. Internal logic governs Blank, Sync and
Force High so that they override the data inputs as
needed in video applications. Sync overrides both the
data and other controls to produce full negative video
output (figure 4).
Reference White video level output is provided by Force
High, which drives the internal digital data to full-scale
output or 100 IRE units. Bright gives an additional 10% of
full-scale value to the output level. This function can be
used in graphic displays for highlighting menus, cursors
or warning messages. Again, if the devices are used in
non-video applications, the video controls can be left
open.
Normal High (White)
256 Gray Levels
Video
Normal Low (Black)
7.5
0
–728 mV
–781 mV
Blank
–40 –1071 mV
Sync
SPT5140
7
3/28/00