BMA253
Data sheet
Page 99
The basic write operation waveform for 4-wire configuration is depicted in figure 14. During the
entire write cycle SDO remains in high- impedance state.
CSB
SCK
SDI
R/W AD6 AD5 AD4 AD3 AD2 AD1 AD0 DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0
SDO
Z
tri-state
Figure 14: 4-wire basic SPI write sequence (mode ´11´)
The basic read operation waveform for 4-wire configuration is depicted in figure 15:
CSB
SCK
SDI
R/W AD6 AD5 AD4 AD3 AD2 AD1 AD0
SDO
DO7 DO6 DO5 DO4 DO3 DO2 DO1 DO0
tri-state
Figure 15: 4-wire basic SPI read sequence (mode ´11´)
BST-BMA253-DS000-01 | Revision 1.0 | August 2015
Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.