Register 0x34 (BGW_SPI3_WDT)
Contains settings for the digital interfaces.
Name
Bit
0x34
7
BGW_SPI3_WDT
6
5
4
Read/Write R/W
R/W
0
R/W
0
R/W
0
Reset
0
Value
Content
reserved
3
Bit
2
1
0
Read/Write R/W
R/W
0
R/W
0
R/W
0
Reset
0
Value
Content
reserved
i2c_wdt_en
i2c_wdt_sel
spi3
reserved:
write ‘0’
i2c_wdt_en:
if I²C interface mode is selected then ‘1´ enable, or ‘0’ disables the
watchdog at the SDI pin (= SDA for I²C)
i2c_wdt_sel:
spi3:
select an I²C watchdog timer period of ‘0’ 1 ms, or ‘1’ 50 ms
select ´0´ 4-wire SPI, or ´1´ 3-wire SPI mode