800
700
600
500
400
300
P
(mW)
S
I
(mA)
S
200
100
0
0
25 50 75 100 125 150 175 200
– CASE TEMPERATURE – °C
T
S
Insulation and Safety Related Specifications
Parameter
Symbol
HCPL-3140
HCPL-0314
Units
Conditions
Minimum External Air Gap
(Clearance)
L(101)
7.1
4.9
mm
Measured from input terminals
to output terminals, shortest
distance through air.
Minimum External Tracking
(Creepage)
L(102)
7.4
4.8
mm
mm
Measured from input terminals
to output terminals, shortest
distance path along body.
Minimum Internal Plastic Gap
(Internal Clearance)
0.08
0.08
Through insulation distance
conductor to conductor, usually
the straight line distance
thickness between the emitter
and detector.
Tracking Resistance
(Comparative Tracking Index)
CTI
>175
IIIa
>175
IIIa
V
DIN IEC 112/VDE 0303 Part 1
Isolation Group
Material Group (DIN VDE
0110, 1/89, Table 1)
Absolute Maximum Ratings
Parameter
Symbol
TS
Min.
-55
Max.
125
100
25
Units
°C
Note
Storage Temperature
OperatingTemperature
Average InputCurrent
TA
-40
°C
IF(AVG)
IF(TRAN)
mA
A
1
Peak Transient Input Current (<1 µs pulse
1.0
width, 300pps)
Reverse InputVoltage
“High” Peak Output Current
“Low” Peak Output Current
SupplyVoltage
VR
5
V
IOH(PEAK)
IOL(PEAK)
0.6
0.6
35
A
2
2
A
V -V
CC EE
-0.5
-0.5
V
Output Voltage
VO(PEAK)
PO
V
V
CC
OutputPowerDissipation
InputPowerDissipation
LeadSolderTemperature
SolderReflowTemperature Profile
250
45
mW
mW
3
4
PI
260°C for 10 sec., 1.6 mm below seating plane
See Package Outline Drawings section
5