IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060)
Characteristic
ACPL-061L
Description
Symbol
ACPL-C61L
ACNW261L
Unit
Installation classification per DIN VDE 0110/39, Table 1
for rated mains voltage ≤ 150 Vrms
I – IV
I – III
I – II
I – IV
I – IV
I – IV
I – III
I – IV
I – IV
I – IV
I – III
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
for rated mains voltage ≤ 1000 Vrms
Climatic Classification
55/105/21
55/105/21
2
55/105/21
2
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
2
VIORM
VPR
567
1063
1414
2651
1414
2651
Vpeak
Vpeak
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec,
Partial discharge < 5 pC
VPR
907
2262
8000
2262
8000
Vpeak
Highest Allowable Overvoltage
VIOTM
6000
Vpeak
(Transient Overvoltage tini = 60 sec)
Safety-limiting values – maximum values allowed in the
event of a failure.
Case Temperature
Input Current**
Output Power**
TS
IS, INPUT
PS, OUTPUT 600
150
150
175
230
600
150
400
700
°C
mA
mW
Insulation Resistance at TS, VIO = 500 V
RS
>109
>109
>109
W
*
Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test profiles.
** Refer to the following figure for dependence of P and I on ambient temperature.
S
S
Surface Mount SO-8 Product
P (mW)
Surface Mount SSO-8 Product
Widebody 400mil DIP-8 Product
P (mW)
1000
800
600
400
200
0
700
1000
900
800
700
600
500
400
300
200
P (mW)
I (mA)
S
S
S
S
I (mA)
S
I (mA)
S
600
500
400
300
200
100
0
100
0
0
25
50
75
100 125 150 175
0
25 50 75 100 125 150 175 200
0
25
50
75
100 125 150 175
T – CASE TEMPERATURE – °C
S
T – CASE TEMPERATURE – °C
S
T – CASE TEMPERATURE – °C
S
6