欢迎访问ic37.com |
会员登录 免费注册
发布采购

ATMEGA32L-8AUR 参数 Datasheet PDF下载

ATMEGA32L-8AUR图片预览
型号: ATMEGA32L-8AUR
PDF下载: 下载PDF文件 查看货源
内容描述: [RISC Microcontroller, 8-Bit, FLASH, AVR RISC CPU, 8MHz, CMOS, PQFP44, 10 X 10 MM, 1 MM HEIGHT, 0.80 MM PITCH, GREEN, PLASTIC, MS-026ACB, TQFP-44]
分类和应用: 闪存微控制器
文件页数/大小: 347 页 / 3171 K
品牌: ATMEL [ ATMEL ]
 浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第263页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第264页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第265页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第266页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第268页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第269页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第270页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第271页  
ATmega32(L)  
Programming the Lock Bits  
The algorithm for programming the Lock bits is as follows (refer to “Programming the  
Flash” on page 262 for details on Command and Data loading):  
1. A: Load Command “0010 0000”.  
2. C: Load Data Low Byte. Bit n = “0” programs the Lock bit.  
3. Give WR a negative pulse and wait for RDY/BSY to go high.  
The Lock bits can only be cleared by executing Chip Erase.  
Reading the Fuse and Lock  
Bits  
The algorithm for reading the Fuse and Lock bits is as follows (refer to “Programming  
the Flash” on page 262 for details on Command loading):  
1. A: Load Command “0000 0100”.  
2. Set OE to “0”, BS2 to “0” and BS1 to “0”. The status of the Fuse Low bits can  
now be read at DATA (“0” means programmed).  
3. Set OE to “0”, BS2 to “1” and BS1 to “1”. The status of the Fuse High bits can  
now be read at DATA (“0” means programmed).  
4. Set OE to “0”, BS2 to “0” and BS1 to “1”. The status of the Lock bits can now be  
read at DATA (“0” means programmed).  
5. Set OE to “1”.  
Figure 132. Mapping between BS1, BS2 and the Fuse- and Lock Bits during Read  
Fuse Low Byte  
0
DATA  
0
1
Lock Bits  
1
BS1  
Fuse High Byte  
BS2  
Reading the Signature Bytes  
The algorithm for reading the Signature bytes is as follows (refer to “Programming the  
Flash” on page 262 for details on Command and Address loading):  
1. A: Load Command “0000 1000”.  
2. B: Load Address Low Byte ($00 - $02).  
3. Set OE to “0”, and BS1 to “0”. The selected Signature byte can now be read at  
DATA.  
4. Set OE to “1”.  
Reading the Calibration Byte  
The algorithm for reading the Calibration byte is as follows (refer to “Programming the  
Flash” on page 262 for details on Command and Address loading):  
1. A: Load Command “0000 1000”.  
2. B: Load Address Low Byte, $00.  
3. Set OE to “0”, and BS1 to “1”. The Calibration byte can now be read at DATA.  
4. Set OE to “1”.  
267  
2503J–AVR–10/06  
 复制成功!