欢迎访问ic37.com |
会员登录 免费注册
发布采购

AT89S8252_06 参数 Datasheet PDF下载

AT89S8252_06图片预览
型号: AT89S8252_06
PDF下载: 下载PDF文件 查看货源
内容描述: 8位微控制器8K字节的Flash [8-bit Microcontroller with 8K Bytes Flash]
分类和应用: 微控制器
文件页数/大小: 41 页 / 479 K
品牌: ATMEL [ ATMEL ]
 浏览型号AT89S8252_06的Datasheet PDF文件第3页浏览型号AT89S8252_06的Datasheet PDF文件第4页浏览型号AT89S8252_06的Datasheet PDF文件第5页浏览型号AT89S8252_06的Datasheet PDF文件第6页浏览型号AT89S8252_06的Datasheet PDF文件第8页浏览型号AT89S8252_06的Datasheet PDF文件第9页浏览型号AT89S8252_06的Datasheet PDF文件第10页浏览型号AT89S8252_06的Datasheet PDF文件第11页  
AT89S8252  
Table 2. T2CON – Timer/Counter 2 Control Register  
T2CON Address = 0C8H  
Reset Value = 0000 0000B  
Bit Addressable  
TF2  
7
EXF2  
6
RCLK  
5
TCLK  
4
EXEN2  
3
TR2  
2
C/T2  
1
CP/RL2  
0
Bit  
Symbol  
Function  
TF2  
Timer 2 overflow flag set by a Timer 2 overflow and must be cleared by software. TF2 will not be set when either  
RCLK = 1 or TCLK = 1.  
EXF2  
Timer 2 external flag set when either a capture or reload is caused by a negative transition on T2EX and EXEN2 = 1.  
When Timer 2 interrupt is enabled, EXF2 = 1 will cause the CPU to vector to the Timer 2 interrupt routine. EXF2 must be  
cleared by software. EXF2 does not cause an interrupt in up/down counter mode (DCEN = 1).  
RCLK  
TCLK  
Receive clock enable. When set, causes the serial port to use Timer 2 overflow pulses for its receive clock in serial port  
Modes 1 and 3. RCLK = 0 causes Timer 1 overflows to be used for the receive clock.  
Transmit clock enable. When set, causes the serial port to use Timer 2 overflow pulses for its transmit clock in serial port  
Modes 1 and 3. TCLK = 0 causes Timer 1 overflows to be used for the transmit clock.  
EXEN2  
Timer 2 external enable. When set, allows a capture or reload to occur as a result of a negative transition on T2EX if  
Timer 2 is not being used to clock the serial port. EXEN2 = 0 causes Timer 2 to ignore events at T2EX.  
TR2  
Start/Stop control for Timer 2. TR2 = 1 starts the timer.  
C/T2  
Timer or counter select for Timer 2. C/T2 = 0 for timer function. C/T2 = 1 for external event counter (falling edge  
triggered).  
CP/RL2  
Capture/Reload select. CP/RL2 = 1 causes captures to occur on negative transitions at T2EX if EXEN2 = 1. CP/RL2 = 0  
causes automatic reloads to occur when Timer 2 overflows or negative transitions occur at T2EX when EXEN2 = 1. When  
either RCLK or TCLK = 1, this bit is ignored and the timer is forced to auto-reload on Timer 2 overflow.  
7
0401G–MICRO–3/06  
 复制成功!