Status 0xF8 indicates that no relevant information is available because the TWINT Flag is not
set. This occurs between other states, and when the TWI is not involved in a serial transfer.
Status 0x00 indicates that a bus error has occurred during a 2-wire Serial Bus transfer. A bus
error occurs when a START or STOP condition occurs at an illegal position in the format frame.
Examples of such illegal positions are during the serial transfer of an address byte, a data byte,
or an acknowledge bit. When a bus error occurs, TWINT is set. To recover from a bus error, the
TWSTO Flag must set and TWINT must be cleared by writing a logic one to it. This causes the
TWI to enter the not addressed Slave mode and to clear the TWSTO Flag (no other bits in
TWCR are affected). The SDA and SCL lines are released, and no STOP condition is
transmitted.
Table 20-7. Miscellaneous States
Status Code
(TWSR)
Prescaler Bits
are 0
Application Software Response
To TWCR
Status of the 2-wire Serial Bus
and 2-wire Serial Interface
Hardware
To/from TWDR
STA
STO
TWIN
T
TWE
A
Next Action Taken by TWI Hardware
Wait or proceed current transfer
0xF8
0x00
No relevant state information
available; TWINT = “0”
No TWDR action
No TWDR action
No TWCR action
Bus error due to an illegal
START or STOP condition
0
1
1
X
Only the internal hardware is affected, no STOP condi-
tion is sent on the bus. In all cases, the bus is released
and TWSTO is cleared.
20.8.6
Combining Several TWI Modes
In some cases, several TWI modes must be combined in order to complete the desired action.
Consider for example reading data from a serial EEPROM. Typically, such a transfer involves
the following steps:
1. The transfer must be initiated.
2. The EEPROM must be instructed what location should be read.
3. The reading must be performed.
4. The transfer must be finished.
Note that data is transmitted both from Master to Slave and vice versa. The Master must instruct
the Slave what location it wants to read, requiring the use of the MT mode. Subsequently, data
must be read from the Slave, implying the use of the MR mode. Thus, the transfer direction must
be changed. The Master must keep control of the bus during all these steps, and the steps
should be carried out as an atomical operation. If this principle is violated in a multimaster sys-
tem, another Master can alter the data pointer in the EEPROM between steps 2 and 3, and the
Master will read the wrong data location. Such a change in transfer direction is accomplished by
transmitting a REPEATED START between the transmission of the address byte and reception
of the data. After a REPEATED START, the Master keeps ownership of the bus. The following
figure shows the flow in this transfer.
Figure 20-20. Combining Several TWI Modes to Access a Serial EEPROM
Master Transmitter
Master Receiver
S
SLA+W
A
ADDRESS
A
Rs
SLA+R
A
DATA
A
P
S = START
Transmitted from master to slave
Rs = REPEATED START
Transmitted from slave to master
P = STOP
244
AT90USB64/128
7593A–AVR–02/06