 浏览型号90USB1287-16AU的Datasheet PDF文件第217页浏览型号90USB1287-16AU的Datasheet PDF文件第218页浏览型号90USB1287-16AU的Datasheet PDF文件第219页浏览型号90USB1287-16AU的Datasheet PDF文件第220页浏览型号90USB1287-16AU的Datasheet PDF文件第222页浏览型号90USB1287-16AU的Datasheet PDF文件第223页浏览型号90USB1287-16AU的Datasheet PDF文件第224页浏览型号90USB1287-16AU的Datasheet PDF文件第225页  
AT90USB64/128  
20.4 Multi-master Bus Systems, Arbitration and Synchronization  
The TWI protocol allows bus systems with several masters. Special concerns have been taken  
in order to ensure that transmissions will proceed as normal, even if two or more masters initiate  
a transmission at the same time. Two problems arise in multi-master systems:  
• An algorithm must be implemented allowing only one of the masters to complete the  
transmission. All other masters should cease transmission when they discover that they have  
lost the selection process. This selection process is called arbitration. When a contending  
master discovers that it has lost the arbitration process, it should immediately switch to Slave  
mode to check whether it is being addressed by the winning master. The fact that multiple  
masters have started transmission at the same time should not be detectable to the slaves,  
i.e. the data being transferred on the bus must not be corrupted.  
• Different masters may use different SCL frequencies. A scheme must be devised to  
synchronize the serial clocks from all masters, in order to let the transmission proceed in a  
lockstep fashion. This will facilitate the arbitration process.  
The wired-ANDing of the bus lines is used to solve both these problems. The serial clocks from  
all masters will be wired-ANDed, yielding a combined clock with a high period equal to the one  
from the Master with the shortest high period. The low period of the combined clock is equal to  
the low period of the Master with the longest low period. Note that all masters listen to the SCL  
line, effectively starting to count their SCL high and low time-out periods when the combined  
SCL line goes high or low, respectively.  
Figure 20-7. SCL Synchronization Between Multiple Masters  
TA low  
TA high  
SCL from  
Master A  
SCL from  
Master B  
SCL Bus  
Line  
TBlow  
TBhigh  
Masters Start  
Masters Start  
Counting Low Period  
Counting High Period  
Arbitration is carried out by all masters continuously monitoring the SDA line after outputting  
data. If the value read from the SDA line does not match the value the Master had output, it has  
lost the arbitration. Note that a Master can only lose arbitration when it outputs a high SDA value  
while another Master outputs a low value. The losing Master should immediately go to Slave  
mode, checking if it is being addressed by the winning Master. The SDA line should be left high,  
but losing masters are allowed to generate a clock signal until the end of the current data or  
address packet. Arbitration will continue until only one Master remains, and this may take many  
221  