Configuration of options Note: Options described as "factory-installed options" must be specified when ordering and cannot be installed by the user. Note: Product names appearing in this catalog are trademarks or registered trademarks of various companies.
Input modules
Logic signal measurement
Install by inserting into the main unit. Can be replaced by user.
ANALOG UNIT 8956
HIGH RESOLUTION UNIT 8957
16ch SCANNER UNIT 8958
DC/RMS UNIT 8959
STRAIN UNIT 8960
HIGH VOLTAGE UNIT 8961
Up to four units settable for the 8861-50 one main unit
CONVERSION CABLE 9ꢁꢀꢁ
Used for connecting the 9ꢁꢀ0/9ꢁꢀ1 and
8860 series MEMORY HiCORDERs,
because the terminal shapes are different.
LOGIC PROBE 9ꢁꢀ7
4-channel type, for voltage/contact
signal ON/OFF detection (high-speed,
miniature terminal type)
LOGIC PROBE 9ꢁꢀ0-01
4-channel type, for voltage/
contact signal ON/OFF detection
(miniature terminal type)
LOGIC PROBE 9ꢁꢀ1-01
4 isolated channels, ON/OFF
detection of AC/DC voltage
(miniature terminal type)
* This cable is not required for the small-
terminal types 9ꢁꢀ7, 9ꢁꢀ0-01, and
9ꢁꢀ1-01.
ANALOG UNIT 89ꢁ6
VOLTAGE/TEMP UNIT 89ꢁ7
FFT ANALOG UNIT 89ꢁ8
Current measurement * The 3274, 3275, and 3276 cannot be used for the F/V UNIT 8940
F/V UNIT 8940
9ꢀ79 Not CE certified
Input cables are not supplied. Please purchase the STRAIN UNIT 89ꢁ9
appropriate cable for the intended application.
ꢁꢀ7ꢁ-50
9ꢀ77
F/V UNIT 8940
4ch ANALOG UNIT 8946
CHARGE UNIT 8947
CONVERSION CABLE 9ꢁ19 (to connect ꢁꢀ7ꢁ-50 and 8940)
9ꢀ78
CONVERSION CABLE 9ꢁ18 (to connect 9ꢀ77 - 9ꢀ79 and 8940)
UNIVERSAL CLAMP ON CT 9ꢀ77 CONVERSION CABLE 9ꢁ18
Observe waveforms from DC to distorted
AC. DC to 100kHz response, input 20A /
output 2V AC
to connect 9ꢀ77/9ꢀ78/9ꢀ79 and 8940
CONVERSION CABLE 9ꢁ19
to connect ꢁꢀ7ꢁ-50 and 8940
Voltage measurement
use only with the 8961 module
UNIVERSAL CLAMP ON CT 9ꢀ78
Observe waveforms from DC to distorted
AC. DC to 100kHz response, input 200A /
output 2V AC
CLAMP ON PROBE ꢁꢀ7ꢁ-50
DC to 50MHz wideband response,
mA-class current up to 30A rms
UNIVERSAL CLAMP ON CT 9ꢀ79
Observe waveforms from DC to distorted
AC. DC to 20kHz response, input 500A /
output 2V AC
GRABBER CLIP 9ꢀ4ꢁ
For use with the 9ꢀ4ꢀ
MEMORY HiCORDER 8860-50
CONNECTION CORD 9ꢀ4ꢀ
CONNECTION CORD 9ꢀ17
Cord has insulated BNC
connectors at both ends, and
connects to the 9555-10 and
input module.
(Standard supplied accessories)
For use with the 8961
The MEMORY HiCORDER 8860-50 cannot operate alone. You must
*
install one or more optional input modules in the unit. When ordering,
(Standard supplied accessories)
*
specify one memory board for the 8860-50.
SENSOR UNIT 9555-10
Model 9555-10 is required to power the Clamp-
Voltage measurement for use with general input moduls
On CTs, except for connecting Clamp-On CT
Models 9ꢀ77/78/79 to Model 8940, and for
signal output, Model 9ꢀ17 Connection Cord is
required to connect for the input modules.
MEMORY HiCORDER 8861-50
The MEMORY HiCORDER 8861-50 cannot operate alone. You must
*
install one or more optional input modules in the unit. When ordering,
*
specify two memory boards of the same capacity for the 8861-50.
Current measurement *connect to the Analog input module
CONNECTION CORD
CONNECTION CORD
ꢁꢀ7ꢀ
9197
9198
ꢁꢀ74
ꢁꢀ75
ꢁꢀ7ꢁ-50
ꢁꢀ76
For high voltage (up to 500V)
For low voltage (up to 300V)
ꢁꢀ69
Note: Memory boards are not built in as a
standard feature. Choose from the following
CLAMP ON PROBE ꢁꢀ7ꢁ-50 POWER SUPPLY ꢁꢀ7ꢀ
DC to 50MHz wideband response,
mA-class current up to 30A rms
Connect and power up to one CLAMP
ON PROBE to use in combination with
voltage input modules
HD UNIT 9718-50
memory boards for factory pre-installation -
one board for Model 8860-50, and two of the
same capacity for the 8861-50.
Factory-installed option. 60GB
CLAMP ON PROBE ꢁꢀ74
DC to 10MHz wideband response,
mA-class current up to 150A rms
100:1 PROBE 9666
Max. rated voltage to earth is same as
for input module, max. input voltage
5kV peak (up to 1MHz)
10:1 PROBE 9665
Max. rated voltage to earth is same as
for input module, max. input voltage
1kV rms (up to 1MHz)
POWER SUPPLY ꢁꢀ69
Connect and power up to four CLAMP
ON PROBEs to use in combination
with voltage input modules
MEMORY BOARD 9715-50
(32 Megaword capacity)
CLAMP ON PROBE ꢁꢀ75
DC to 2MHz wideband response,
mA-class current up to 500A rms
Either the DC power
*
unit 9684 or the probe
power unit 9687 may be
used. If you want to use
both at the same time,
consult us.
MEMORY BOARD 9715-51
Either the DC power unit 9684 or the probe
*
(128 Megaword capacity)
power unit 9687 may be used. If you want to
use both at the same time,
consult us.
Voltage measurement for use with general input moduls
CLAMP ON PROBE ꢁꢀ76
DC to 100MHz wideband response,
mA-class current up to 30A rms
MEMORY BOARD 9715-5ꢀ
(512 Megaword capacity)
DC POWER UNIT 9684
Factory-installed option, not user
installable, build in on the bottom case.
12V DC drive.
MEMORY BOARD 9715-5ꢁ
PROBE POWER UNIT 9687
Factory-installed option, not user installable,
build in on the bottom case. For up to five or
more Clamp on probes ꢁꢀ7ꢁ-50 to ꢁꢀ76,
or Differential probe 9ꢁꢀꢀ.
(1 Gigaword capacity)
DIFFERENTIAL PROBE 9ꢁꢀꢀ AC ADAPTER 9418-15
MEMORY BACKUP UNIT 9719
For up to 2kV DC or 1kV AC, AC
adapter 9418-15 required, or Probe
power unit 9687 and Power cord
9ꢀ48 required for operation.
For powering Differential probe
Factory-installed option. Internal type.
9ꢁꢀꢀ, 100 to 240V AC, 12V/2.5 A
PC Communication
PROBE POWER UNIT 9687 POWER CORD 9ꢀ48
Factory-installed option, not user installable, to connect Differential probe
build in on the bottom case. For up to eight
9ꢁꢀꢀ and Probe power unit 9687
probes exclusive the Differential probe 9ꢁꢀꢀ.
LAN CABLE 964ꢀ
Straight Ethernet cable, supplied with
straight to cross conversion cable, cable
length: 5 m (16.41 ft)
MEMORY HiVIEWER 97ꢀ5
Functions identical to those of the 8860s run
on Windows 2000/XP compatible computers
Printer options
RECORDING PAPER 9ꢀꢁ1
(for A4-printer 8995 only)
A4 width 216 mm (8.50 in) × 30 m
(98.43 ft), 6 rolls
Other options
A4 PRINTER UNIT 8995
Factory-installed option. Either 8995 or
8995-01 printer can be installed. Printing
width 200 mm (7.87 inch).
CONNECTION CORD 9ꢀ17
Cord has insulated BNC connectors at
both ends, and connects to insulated
BNC connectors on input module
CONNECTION CORD 9165
Cord has metallic BNC connectors at
both ends, and connects to metallic BNC
connectors such as trigger terminals
Supplied with PC
Card adapter
PC CARD 1ꢀ8M 97ꢀ6
Not CE certified
(128MB capacity)
PC CARD ꢀ56M 97ꢀ7
PAPER WINDER ꢀꢀ0H
Paper width 70 to 220 mm (2.76 to
8.66 inch), 100V AC Only
CARRYING CASE 97ꢀꢁ
(256MB capacity)
For only the 8860, hard trunk
PC Card Precaution
PC CARD 51ꢀM 97ꢀ8
type
Use only PC Cards sold
by HIOKI. Compatibility
and performance are not
guaranteed for PC cards made
by other manufacturers. You
may be unable to read from or
save data to such cards.
(512MB capacity)
A6 PRINTER UNIT 8995-01
Factory-installed option. Either 8995 or
8995-01 printer can be installed. Printing
width 100 mm (3.94 inch).
PC CARD 1G 97ꢀ9
RECORDING PAPER 9ꢀꢁ4
(for A6-printer 8995-01 only)
A6 width 112 mm (4.41 in) × 18
m (59.06 ft), 10 rolls
CONVERSION ADAPTER 9199
Banana-to-BNC, use to connect to BNC
terminal on Input Module
CARRYING CASE 97ꢀ4
For only the 8861, hard trunk
type
(1GB capacity)
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
1904 Shanghai Times Square Office, 93 Huai Hai Zhong Road
Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
E-mail: info-sh@hioki.cn
DISTRIBUTED BY
Beijing Office :
HEAD OFFICE :
A-2602 Freetown, 58 Dong San Huan Nan Road
Beijing, P.R.China POSTCODE: 100022
TEL +86-10-586ꢀ-4080/4081 FAX +86-10-586ꢀ-4090
E-mail: info-bj@hioki.cn
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: os-com@hioki.co.jp
Guangzhou Office :
HIOKI USA CORPORATION :
Room 303, Profit Plaza, No.ꢀ6, West Huangpu Road
Guangzhou, P.R.China POSTCODE: 510623
TEL +86-20-383926ꢀ3/26ꢀ6 FAX +86-20-383926ꢀ9
E-mail: info-gz@hioki.cn
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: hioki@hiokiusa.com
All information correct as of Sep. 12, 2007. All specifications are subject to change without notice.
8860-50E1-79M-05P Printed in Japan