15
n
Options specifications (sold separately)
Perform the same functions on the computer
Features
n
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 30 cm
(0.98 ft), approx. 150 g (5.3 oz)
1) Application software enables you to
perform the same data analysis on a
Windows computer as on the MEMORY
HiCORDERs 8860 series.
2) No confusion, because the screens
appearing on the computer are identical
to those of the 8860 series.
3) Functions identical to those of the 8860
series, such as waveform processing
calculation, run on the computer.
Note: The unit-side plug of the 9320-01 and 9327 is different from the 9320.
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed
for 1 year)
LOGIC PROBE 9ꢁꢀ0-01/9ꢁꢀ7
Detection of voltage signal or relay contact signal for High/Low state recording
Function
4 channels (common ground between unit and channels), digital/contact input,
switchable (contact input can detect open-collector signals), input impedance:
1MΩ (with digital input, 0 to +5V), 500kΩ or more (with digital input, +5 to
+50V), pull-up resistance: 2kΩ (contact input: internally pulled up to +5V)
Input
1.4V/2.5V/4.0V
Digital input threshold
MEMORY HiVIEWER 97ꢀ5
1.5kΩ or higher (open) and 500Ω or lower (short), 3.5kΩ or higher (open) and
1.5kΩ or lower (short), 25kΩ or higher (open) and 8kΩ or lower (short)
Contact input
detection resistance
MEMORY HiCORDER 8860-50, 8861-50, 8860, 8861
Compatible devices
Supplied Media
Operating environment
One CD-R disc
Response speed 9ꢁꢀ0-01: 500ns or lower, 9ꢁꢀ7: detectable pulse width 100ns or higher
Computer running under Windows 2000/XP
0 to +50V DC (the maximum voltage that can be applied across input pins without damage)
Max. allowable input
Readable data formats : Only for 8860 series data (.MEM, .REC,
.FFT, .SEQ, .IDX, .SET)
Maximum file size : 2 GW
File loading
File saving
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 1 m (3.28 ft),
approx. 320 g (11.3 oz)
Note: The unit-side plug of the 9321-01 is different from the 9321.
Saved contents: measurement data (binary and ASCII), (partial
saving of the area between cursors A and B), setting conditions,
screen image (BMP, PNG), and calculation results
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh; accuracy guaranteed
for 1 year)
LOGIC PROBE 9ꢁꢀ1-01
Detection of AC or DC relay drive signal for High/Low state recording
Can also be used for power line interruption detection
Function
Waveform display: 1-, 2-, 3-, 4-, 6-, and 8-split screen, horizontal,
vertical, consecutive scroll, and zoom in/out along the time
axis, move the zero position, zoom in/out, setting of variables
independently for each channel
4 channels (isolated between unit and channels), HIGH/LOW range switching
Input impedance: 100kΩ or higher (HIGH range), 30kΩ or higher (LOW range)
Input
X-Y-axis composite display (for the MEM function only): 1-, 2-, and
4-split display, dot/line interpolation, composite area can be
specified
Numerical display: digital values of waveform data can be displayed
Display sheet: 16 sheets
170 to 250V AC, ±DC (70 to 250V ) (HIGH range)
60 to 150V AC, ±DC (20 to 150V) (LOW range)
Output (H)
detection
0 to 30V AC, ±DC (0 to 43V) (HIGH range)
0 to 10V AC, ±DC (0 to 15V) (LOW range)
Output (L)
detection
Display
Display channel count (per sheet): 32 analog channels, 16 logic
Rising edge 1ms max., falling edge 3ms max. (with HIGH range at
200V DC, LOW range at 100V DC)
Response time
channels, 16 calculated waveforms, 8 X-Y-axis composite waveforms
Cursor function: vertical cursor, horizontal cursor, trace cursor, two
cursors (cursor A and cursor B), time and voltage display
Clipboard copy: images on the waveform screen can be transferred
to the clipboard
250Vrms (HIGH range), 150Vrms (LOW range) (the maximum voltage
that can be applied across input pins without damage)
Maximum allowable
input voltage
Cable length and mass: Main unit cable 1.3 m (4.27 ft), input section cable 46 cm
(1.51 ft), approx. 350 g (12.3 oz)
Supported printer: printer compatible with the OS
Print format: waveform image (1-, 2-, 3-, 4-, 6-, 8-, and
16-split), numerical print, report format, list print, calculation
results, screen image
Print area: the entire area, area between cursors A and B
Print preview: supported
(Accuracy at 23 ±5°C/73 ±9°F, 35 to 80% rh, after 30 minutes of
DIFFERENTIAL PROBE 9ꢁꢀꢀ
warm-up time; accuracy guaranteed for 1 year)
Print
For high-voltage floating measurement, power line surge noise
detection, RMS rectified output measurement
Function
For waveform monitor output, frequency characteristics: DC to 10MHz
(±3dB), amplitude accuracy: ±1% of full scale (at max. 1000V DC), ±3%
of full scale (at max. 2000V DC) (full scale: 2000V DC)
DC mode
AC mode
RMS mode
For detection of power line surge noise, frequency characteristics: 1kHz to 10MHz ±3dB
DC/AC voltage RMS output detection, frequency characteristics: DC, 40Hz to
100kHz, response speed: 200ms or less (400V AC), accuracy: ±1% of full scale
(DC, 40Hz to 1kHz), ±4% of full scale (1kHz to 100kHz) (full scale: 1000V AC)
Input type: balanced differential input, input impedance/capacitance:
H-L 9MΩ/10pF, H/L-unit 4.5MΩ/20pF, Max. rated voltage to earth:
when using grabber clip 1500V AC/DC (CAT II ), 600V AC/DC (CAT III),
when using alligator clip: 1000V AC/DC (CAT II), 600V AC/DC (CAT III)
Input
2000V DC, 1000V AC (CAT II), 600V AC/DC (CAT III)
Maximum allowable input
Voltage divider for 1/1000 of input, BNC connectors (output switchable for
3 modes DC, AC, RMS)
Output
(1) Connect the AC ADAPTER 9418-15, (2) Connect to the PROBE POWER
UNIT 9687 via the POWER CORD 9ꢀ48, (3) Connect to HiCORDER logic
terminal via the POWER CORD 9ꢁꢀ4 and CONVERSION CABLE 9ꢁꢀꢁ,
(4) Connect to the F/V UNIT 8940 via the POWER CORD 9ꢁꢀ5.
Power source
Dimensions and mass: approx. 315.8 (12.43in) W × 29 (1.14in) H × 244.4 (9.62in) D mm,
approx. 1.25 kg (44.1oz) Accessories: None
DC POWER UNIT 9684
Note: Factory-installed option, build in on the bottom case of the main unit
12V DC (input range : 10 to 16V DC)
Rated input voltage
200VA (printer used)
Power requirements
Note: Either the DC power unit 9684 or the probe power unit 9687 may be used. If you want to use both at the same time, consult us.
Dimensions and mass: approx. 315.8 (12.43in) W × 18.2 (0.72in) H × 244.4 (9.62in) D mm,
approx. 570 g (20.1oz) Accessories: None
n
PC Software Specifications Note: With use of the 8860-50/8861-50 , Wv ver 1.25 or later
Wave Viewer (Wv) Software (Application disk CD-R, bundled accessory)
PROBE POWER UNIT 9687
Note: Factory-installed option, build in on the bottom case of the main unit
8 Channels, Output current: Up to 3 A total (Total combined current
consumption of connected probes should be no more than 3 A)
• Simple display of waveform file
• Text conversion: convert binary data file to text format,
with selectable space or tab separators in addition to CSV,
and specifiable section, thinning available
• Display format settings: scroll functions, enlarge/reduce
display, display channel settings
• Others: voltage value trace function, jump to cursor/trig-
ger position function
No. of powerd channels
Compatible current probes
ꢁꢀ7ꢁ (0.25 A max. current consumption): exclusive, up to 8 probes
ꢁꢀ7ꢁ-50 (0.47 A max. current consumption): exclusive, up to 6 probes
ꢁꢀ74 (0.46 A max. current consumption): exclusive, up to 6 probes
ꢁꢀ75 (0.60 A max. current consumption): exclusive, up to 5 probes
ꢁꢀ76 (0.44 A max. current consumption): exclusive, up to 6 probes
Functions
Compatible voltage probes
9ꢁꢀꢀ (0.15 A max. current consumption): exclusive, up to 8 probes
Windows 95/98/Me, Windows NT 4.0 (SP3 or later), 2000, XP
Compatible PC operating systems
Note: Either the DC power unit 9684 or the probe power unit 9687 may be used. If you want to use both at the same time, consult us.