AWT6631
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PARAMETER
MIN
0
MAX
+5
UNIT
V
Supply Voltage (VCC
)
Battery Voltage (VBATT
Control Voltages (VMODE1, VENABLE
RF Input Power (PIN
Storage Temperature (TSTG
)
0
+6
V
)
0
+3.5
+10
+150
V
)
-
dBm
°C
)
-40
Stresses in excess of the absolute ratings may cause permanent damage.
Functional operation is not implied under these conditions. Exposure to
absolute ratings for extended periods of time may adversely affect reliability.
Table 3: Operating Ranges
PARAMETER
MIN
+0.5
+3.1
TYP
+3.4
+3.4
MAX
+4.35
+4.35
UNITS
COMMENTS
Supply Voltage (VCC)
Battery Voltage (VBATT)
V
V
POUT ≤ +28.25 dBm
POUT ≤ +28.25 dBm
+1.35
0
+1.8
0
+3.1
+0.5
PA “on”
PA “shut down”
Enable Voltage (VENABLE)
V
+1.35
0
+1.8
0
+3.1
+0.5
Low Bias Mode
High Bias Mode
Mode Control Voltage (VMODE1)
V
Case Temperature (TC)
-30
-
+90
°C
The device may be operated safely over these conditions; however, parametric performance is guaranteed only
overꢀtheꢀconditionsꢀdefinedꢀinꢀtheꢀelectricalꢀspecifications.
Data Sheet - Rev 2.7
03/2012
3