A625308A Series
Recommended DC Operating Conditions
(TA = 0°C to +70°C, -25°C to +85°C or -40°C to +85°C)
Symbol
VCC
GND
VIH
Parameter
Supply Voltage
Min.
4.5
0
Typ.
Max.
Unit
V
5.0
0
5.5
0
Ground
V
Input High Voltage
Input Low Voltage
2.2
-0.5
-
VCC + 0.5
+0.8
V
VIL
0
V
Absolute Maximum Ratings*
*Comments
VCC to GND . . . . . . . . . . . . . . . . . . . . . . -0.5V to +7.0V
IN, IN/OUT Volt to GND . . . . . . . . . -0.5V to VCC + 0.5V
Stresses above those listed under "Absolute Maximum
Ratings" may cause permanent damage to the device.
These are stress ratings only. Functional operation of this
device at these or any other conditions above those
indicated in the operational sections of this specification
is not implied and exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
Operating Temperature, Topr . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . 0°C to +70°C or -40°C to +85°C
Storage Temperature, Tstg . . . . . . . . . -55°C to +125°C
Power Dissipation, PT . . . . . . . . . . . . . . . . . . . . . . 0.7W
Soldering Temp. & Time . . . . . . . . . . . . . 260°C, 10 sec
DC Electrical Characteristics (TA = 0°C to +70°C, -25°C to +85°C or -40°C to +85°C, VCC = 5.0V ± 10%, GND = 0V)
A625308A-70S/SI/SU
Symbol
Parameter
Unit
Conditions
Min.
Max.
Input Leakage Current
-
1
VIN = GND to VCC
½ILI½
½ILO½
ICC
mA
mA
CE = VIH
VI/O = GND to VCC
Output Leakage Current
Active Power Supply Current
-
-
1
5
mA
CE = VIL, II/O = 0mA
Min. Cycle, Duty = 100%
ICC1
ICC2
Dynamic Operating Current
Dynamic Operating Current
-
-
35
5
mA
mA
CE = VIL, II/O = 0mA
CE = VIL, VIH = VCC
VIL = 0V, f = 1 MHz
II/O = 0 mA
PRELIMINARY
(July, 2002, Version 0.2)
3
AMIC Technology, Inc.