BiCMOS PLL CLOCK GENERATOR
S4402/S4403
ABSOLUTE MAXIMUM RATINGS
Commercial
TTL Supply Voltage VCC (VEE = 0)
7.0 V
TTL Input Voltage (VEE = 0)
Operating Temperature
5.5 V
0°C to 70°C ambient
+ 130°C
Operating Junction Temperature TJ
Storage Temperature
–65°C to +150°C
RECOMMENDED OPERATING CONDITIONS
Commercial
Parameter
Min
Nom
Max
Units
TTL Supply Voltage (VCC)
Operating Temperature
4.75
5.0
—
5.25
V
0
70
°C
(ambient)
(ambient)
Junction Temperature
—
—
130
°C
DC CHARACTERISTICS
1
Symbol
Parameter
DC Test Conditions
Min
Typ
Max Units
Guaranteed input HIGH voltage for
all inputs
2
V
Input HIGH voltage
2.0
V
IH
Guaranteed input LOW voltage for
all inputs
2
V
Input LOW voltage
0.8
V
IL
V
V
Input clamp diode voltage
Output HIGH voltage
V
= Min, I = -18mA
IN
-0.8
-1.2
V
V
IK
CC
CC
3
I
I
I
= -12mA (COM)
2.4
2.0
OH
OH
OL
V
= Min
= Min
OH
OL
3
= -24mA (COM)
V
V
3
V
Output LOW voltage
Input HIGH current
V
CC
V
CC
V
CC
V
CC
= 24mA (COM)
0.5
-200
50
µA
µA
mA
OUTEN2
I
I
I
I
= Min, V = 2.4V
IN
IH
Other
Input HIGH current at max
Input LOW current
= Max, V = V
IN
1.0
I
CC
OUTEN2
Other
-500
-50
µA
µA
= Min, V = 0.5V
IN
IL
4
Output short circuit current
Static
V
V
V
= Max, V
= Max
= 0V
OUT
-100
70
mA
mA
mA
-25
OS
CC
I
I
COM
COM
CC
CC
CC
Total I
(Dynamic and Static)
= 25pF at 50 MHz
190
CC
LOAD
1. Typical limits are at 25°C, VCC = 5.0V.
2. These input levels should only be tested in a static, noise-free environment.
3. IOH/IOL values indicated are for DC test correlation. Actual dynamic currents are
significantly higher and are optimized to balance rise and fall times.
4. Maximum test duration is one second.
Applied Micro Circuits Corporation
6195 Lusk Blvd., San Diego, CA 92121 • (619) 450-9333
Page 8