 浏览型号EP2S90F1020C4N的Datasheet PDF文件第225页浏览型号EP2S90F1020C4N的Datasheet PDF文件第226页浏览型号EP2S90F1020C4N的Datasheet PDF文件第227页浏览型号EP2S90F1020C4N的Datasheet PDF文件第228页浏览型号EP2S90F1020C4N的Datasheet PDF文件第230页浏览型号EP2S90F1020C4N的Datasheet PDF文件第231页浏览型号EP2S90F1020C4N的Datasheet PDF文件第232页浏览型号EP2S90F1020C4N的Datasheet PDF文件第233页  
DC & Switching Characteristics  
Table 5–93. Fast PLL Specifications  
Name Description  
Min  
Typ  
Max  
Unit  
fIN  
Input clock frequency (for -3 and -4 speed  
grade devices)  
16.08  
717  
MHz  
Input clock frequency (for -5 speed grade  
devices)  
16.08  
640  
MHz  
fINPFD  
Input frequency to the PFD  
Input clock duty cycle  
16.08  
40  
500  
60  
MHz  
%
fINDUTY  
tINJITTER  
Input clock jitter tolerance in terms of period  
jitter. Bandwidth 2 MHz  
0.5  
1.0  
ns (p-p)  
Input clock jitter tolerance in terms of period  
jitter. Bandwidth > 2 MHz  
ns (p-p)  
MHz  
fVCO  
Upper VCO frequency range for –3 and –4  
speed grades  
300  
300  
150  
150  
1,040  
840  
Upper VCO frequency range for –5 speed  
grades  
MHz  
Lower VCO frequency range for –3 and –4  
speed grades  
520  
MHz  
Lower VCO frequency range for –5 speed  
grades  
420  
MHz  
fOUT  
4.6875  
150  
550  
1,040  
(1)  
MHz  
MHz  
MHz  
PLL output frequency to GCLKor RCLK  
PLL output frequency to LVDS or DPA clock  
fOUT_IO  
PLL clock output frequency to regular I/O  
pin  
4.6875  
fSCANCLK  
Scanclk frequency  
100  
MHz  
ns  
tCONFIGPLL  
Time required to reconfigure scan chains  
for fast PLLs  
75/fSCANCLK  
fCLBW  
tLOCK  
PLL closed-loop bandwidth  
1.16  
5.00  
0.03  
28.00  
1.00  
MHz  
ms  
Time required for the PLL to lock from the  
time it is enabled or the end of the device  
configuration  
tPLL_PSERR  
Accuracy of PLL phase shift  
15  
ps  
ns  
ns  
tARESET  
10  
Minimum pulse width on aresetsignal.  
tARESET_RECONFIG  
500  
Minimum pulse width on the aresetsignal  
when using PLL reconfiguration. Reset the  
PLL after scandonegoes high.  
Notes to Table 5–93:  