欢迎访问ic37.com |
会员登录 免费注册
发布采购

EP2C50A15Q324C6ES 参数 Datasheet PDF下载

EP2C50A15Q324C6ES图片预览
型号: EP2C50A15Q324C6ES
PDF下载: 下载PDF文件 查看货源
内容描述: Cyclone II器件系列 [Cyclone II Device Family]
分类和应用:
文件页数/大小: 168 页 / 2205 K
品牌: ALTERA [ ALTERA CORPORATION ]
 浏览型号EP2C50A15Q324C6ES的Datasheet PDF文件第12页浏览型号EP2C50A15Q324C6ES的Datasheet PDF文件第13页浏览型号EP2C50A15Q324C6ES的Datasheet PDF文件第14页浏览型号EP2C50A15Q324C6ES的Datasheet PDF文件第15页浏览型号EP2C50A15Q324C6ES的Datasheet PDF文件第17页浏览型号EP2C50A15Q324C6ES的Datasheet PDF文件第18页浏览型号EP2C50A15Q324C6ES的Datasheet PDF文件第19页浏览型号EP2C50A15Q324C6ES的Datasheet PDF文件第20页  
Logic Elements  
Another special packing mode allows the register output to feed back into  
the LUT of the same LE so that the register is packed with its own fan-out  
LUT, providing another mechanism for improved fitting. The LE can also  
drive out registered and unregistered versions of the LUT output.  
In addition to the three general routing outputs, the LEs within an LAB  
have register chain outputs. Register chain outputs allow registers within  
the same LAB to cascade together. The register chain output allows an  
LAB to use LUTs for a single combinational function and the registers to  
be used for an unrelated shift register implementation. These resources  
speed up connections between LABs while saving local interconnect  
resources. See “MultiTrack Interconnect” on page 2–10 for more  
information on register chain connections.  
LE Operating Modes  
The Cyclone II LE operates in one of the following modes:  
Normal mode  
Arithmetic mode  
Each mode uses LE resources differently. In each mode, six available  
inputs to the LE—the four data inputs from the LAB local interconnect,  
the LAB carry-in from the previous carry-chain LAB, and the register  
chain connection—are directed to different destinations to implement the  
desired logic function. LAB-wide signals provide clock, asynchronous  
clear, synchronous clear, synchronous load, and clock enable control for  
the register. These LAB-wide signals are available in all LE modes.  
The Quartus® II software, in conjunction with parameterized functions  
such as library of parameterized modules (LPM) functions, automatically  
chooses the appropriate mode for common functions such as counters,  
adders, subtractors, and arithmetic functions. If required, you can also  
create special-purpose functions that specify which LE operating mode to  
use for optimal performance.  
Normal Mode  
The normal mode is suitable for general logic applications and  
combinational functions. In normal mode, four data inputs from the LAB  
local interconnect are inputs to a four-input LUT (see Figure 2–3). The  
Quartus II Compiler automatically selects the carry-in or the data3  
signal as one of the inputs to the LUT. LEs in normal mode support  
packed registers and register feedback.  
2–4  
Cyclone II Device Handbook, Volume 1  
Altera Corporation  
February 2007  
 复制成功!