ACEX 1K Programmable Logic Device Family Data Sheet
Row-to-IOE Connections
When an IOE is used as an input signal, it can drive two separate row
channels. The signal is accessible by all LEs within that row. When an IOE
is used as an output, the signal is driven by a multiplexer that selects a
signal from the row channels. Up to eight IOEs connect to each side of
each row channel (see Figure 16).
Figure 16. ACEX 1K Row-to-IOE Connections
Note (1)
IOE1
m
Row FastTrack
Interconnect
n
n
n
IOE8
m
13
Each IOE is driven by an
m-to-1 multiplexer.
Each IOE can drive two
row channels.
Note:
(1) The values for m and n are shown in Table 8.
Table 8 lists the ACEX 1K row-to-IOE interconnect resources.
Table 8. ACEX 1K Row-to-IOE Interconnect Resources
Device
Channels per Row (n)
Row Channels per Pin (m)
EP1K10
144
216
216
312
18
27
27
39
EP1K30
EP1K50
EP1K100
Altera Corporation
33