Classic EPLD Family Data Sheet  
Table 17. EP910 & EP910I Device Capacitance  
Note (6)  
Symbol  
Parameter  
Conditions  
EP910  
Max  
EP910I  
Min Max  
Unit  
Min  
CIN  
Input pin capacitance  
I/O pin capacitance  
CLK1pin capacitance  
CLK2pin capacitance  
VIN = 0 V, f = 1.0 MHz  
VOUT = 0 V, f = 1.0 MHz  
VIN = 0 V, f = 1.0 MHz  
VIN = 0 V, f = 1.0 MHz  
20  
20  
20  
60  
8
8
pF  
pF  
pF  
pF  
CI/O  
CCLK1  
CCLK2  
10  
12  
Table 18. EP910 & EP910I Device I Supply Current  
Notes (2), (6), (7)  
CC  
Symbol  
Parameter  
Conditions  
EP910  
EP910I  
Unit  
Min Typ Max Min Typ Max  
ICC1  
ICC2  
ICC3  
VCC supply current  
VI = VCC or ground, no load  
(10), (11)  
20  
150  
60  
150  
µA  
mA  
mA  
(non-Turbo, standby)  
VCC supply current  
(non-Turbo, active)  
VI = VCC or ground, no load,  
f = 1.0 MHz (10), (11)  
6
20  
4
12  
VCC supply current  
(Turbo, active)  
VI = VCC or ground, no load,  
f = 1.0 MHz (11)  
45  
80  
120  
150  
(100)  
Notes to tables:  
(1) See the Operating Requirements for Altera Devices Data Sheet in this data book.  
(2) Numbers in parentheses are for industrial-temperature-range devices.  
(3) The minimum DC input is –0.3 V. During transitions, the inputs may undershoot to –2.0 V (EP910) or  
–0.5 V (EP910I) or overshoot to 7.0 V (EP910) or VCC + 0.5 V (EP910I) for input currents less than 100 mA and periods  
less than 20 ns.  
(4) Maximum VCC rise time for EP910 devices = 50 ms; for EP910I devices, maximum VCC rise time is unlimited with  
monotonic rise.  
(5) For all clocks: tR and tF = 100 ns (50 ns for the industrial-temperature-range version).  
(6) These values are specified in Table 15 on page 770.  
(7) The device capacitance is measured at 25° C and is sample-tested only.  
(8) The IOH parameter refers to high-level TTL or CMOS output current; the IOL parameter refers to low-level TTL  
output current.  
(9) This parameter does not apply to EP910I devices.  
(10) When the Turbo Bit option is not set (non-Turbo mode), an EP910 device will enter standby mode if no logic  
transitions occur for 100 ns after the last transition, and an EP910I device will enter standby mode if no logic  
transitions occur for 75 ns after the last transition.  
(11) Measured with a device programmed as a 24-bit counter.  