Chapter 9: Configuration, Design Security, and Remote System Upgrades in the Cyclone III Device Family  
Document Revision History  
1
1
To allow remote system upgrade dedicated circuitry to reset the watchdog timer, you  
must assert the RU_nRSTIMERsignal active for a minimum of 250 ns. This is equivalent  
to strobing the reset_timerinput of the ALTREMOTE_UPDATE megafunction high  
for a minimum of 250 ns.  
The user watchdog timer is not enabled during the configuration cycle of the device.  
Errors during configuration are detected by the CRC engine. Also, the timer is  
disabled for factory configuration. Functional errors must not exist in the factory  
configuration because it is stored and validated during production and is never  
updated remotely.  
By default, the user watchdog timer is disabled in factory configurations and enabled  
in user-mode application configurations. If you do not want to use the watchdog  
timer feature, disable this feature in the factory configuration.  
Quartus II Software Support  
Implementation in your design requires a remote system upgrade interface between  
the Cyclone III device family logic array and the remote system upgrade circuitry. You  
must also generate configuration files for production and remote programming of the  
system configuration memory. The Quartus II software provides these features.  
The two implementation options, the ALTREMOTE_UPDATE megafunction and the  
remote system upgrade atom, are for the interface between the remote system  
upgrade circuitry and the device logic array interface. Using the megafunction block  
instead of creating your own logic saves design time and offers more efficient logic  
synthesis and device implementation.  
f
For more information about the ALTREMOTE_UPDATE megafunction, refer to the  
Remote Update Circuitry (ALTREMOTE_UPDATE) Megafunction User Guide.  
Document Revision History  
Table 9–32 lists the revision history for this document.  
Table 9–32. Document Revision History (Part 1 of 2)  
Date  
August 2012  
July 2012  
Version  
2.2  
Changes  
Updated Micron P30 and P33 Parallel NOR flash devices.  
Finalized Table 9–3, Table 9–13, and Table 9–14.  
2.1  
Updated “Configuration Features” on page 9–2, “Reset” on page 9–8,“AS Configuration  
(Serial Configuration Devices)” on page 9–12, “Single-Device AS Configuration” on  
page 9–13, “AP Configuration Supported Flash Memory” on page 9–24, “Single-Device  
AP Configuration” on page 9–25, “JTAG Configuration” on page 9–48, and “User  
Watchdog Timer” on page 9–85.  
Removed the “Overriding the Internal Oscillator” section from “JTAG Configuration”.  
December 2011  
2.0  
Updated Figure 9–11, Figure 9–24, Figure 9–25, Figure 9–26, Figure 9–27, Figure 9–29,  
Figure 9–30.  
Updated Table 9–13, Table 9–18, and Table 9–22.  
Replaced links to AN 386: Using the Parallel Flash Loader with the Quartus II Software  
links to Parallel Flash Loader Megafunction User Guide.  
Cyclone III Device Handbook  