AV-51002
2017.02.10
2-65
Active Serial Configuration Timing
Active Serial Configuration Timing
Figure 2-9: AS Configuration Timing
Timing waveform for the active serial (AS) x1 mode and AS x4 mode configuration timing.
t
CF2ST1
nCONFIG
nSTATUS
CONF_DONE
nCSO
DCLK
t
CO
t
DH
Read Address
AS_DATA0/ASDO
AS_DATA1 (1)
INIT_DONE (3)
t
SU
bit (n - 2) bit (n - 1)
bit 1
bit 0
t
(2)
CD2UM
User I/O
User Mode
Notes:
1.If you are using AS ×4 mode, this signal represents the AS_DATA[3..0] and EPCQ sends in 4-bits of data for each DCLKcycle.
2.The initialization clock can be from internal oscillator or CLKUSR pi.n
3.After the option bit to enable the INIT_DONE pin isconfigured into the d evice, the INIT_DONE oges low.
Table 2-58: AS Timing Parameters for AS x1 and AS x4 Configurations in Arria V GZ Devices
e minimum and maximum numbers apply only if you choose the internal oscillator as the clock source for initializing the device.
tCF2CD, tCF2ST0, tCFG, tSTATUS, and tCF2ST1 timing parameters are identical to the timing parameters for PS mode listed in the "PS Timing Parameters
for Arria V GZ Devices" table.
Arria V GZ Device Datasheet
Send Feedback
Altera Corporation