Table 17. LVTTL Interface  
Reference Level of Output Signals  
1.4V / 1.4V  
Output Load  
Input Signal Levels  
Reference to the Under Output Load (B)  
2.4V / 0.4V  
1ns  
Transition Time (Rise and Fall) of Input Signals  
Reference Level of Input Signals  
1.4V  
1.4V  
3.3V  
50Ω  
1.2KΩ  
Output  
Output  
Z0=50Ω  
870Ω  
30pF  
30pF  
Figure 18.1 LVTTL D.C. Test Load (A)  
Figure 18.2 LVTTL A.C. Test Load (B)  
7. Transition times are measured between VIH and VIL. Transition (rise and fall) of input signals are in a fixed slope  
(1 ns).  
8. tHZ defines the time in which the outputs achieve the open circuit condition and are not at reference levels.  
9. If clock rising time is longer than 1 ns, (tR / 2 -0.5) ns should be added to the parameter.  
10. Assumed input rise and fall time tT (tR & tF) = 1 ns  
If tR or tF is longer than 1 ns, transient time compensation should be considered, i.e., [(tr + tf)/2 - 1] ns should be  
added to the parameter.  
11. Power up Sequence  
Power up must be performed in the following sequence.  
1) Power must be applied to VDD and VDDQ (simultaneously) when CKE= LOW”, DQM= HIGHand all input  
signals are held "NOP" state.  
2) Start clock and maintain stable condition for minimum 200 s, then bring CKE HIGHand, it is  
recommended that DQM is held "HIGH" (VDD levels) to ensure DQ output is in high impedance.  
3) All banks must be precharged.  
4) Mode Register Set command must be asserted to initialize the Mode register.  
5) A minimum of 2 Auto-Refresh dummy cycles must be required to stabilize the internal circuitry of the device.  
* The Auto Refresh command can be issue before or after Mode Register Set command  