欢迎访问ic37.com |
会员登录 免费注册
发布采购

AK4367VN 参数 Datasheet PDF下载

AK4367VN图片预览
型号: AK4367VN
PDF下载: 下载PDF文件 查看货源
内容描述: 低功耗24位双声道DAC,具有HP - AMP和输出混音器 [Low Power 24-Bit 2ch DAC with HP-AMP & Output Mixer]
分类和应用: 转换器数模转换器
文件页数/大小: 38 页 / 439 K
品牌: AKM [ ASAHI KASEI MICROSYSTEMS ]
 浏览型号AK4367VN的Datasheet PDF文件第23页浏览型号AK4367VN的Datasheet PDF文件第24页浏览型号AK4367VN的Datasheet PDF文件第25页浏览型号AK4367VN的Datasheet PDF文件第26页浏览型号AK4367VN的Datasheet PDF文件第28页浏览型号AK4367VN的Datasheet PDF文件第29页浏览型号AK4367VN的Datasheet PDF文件第30页浏览型号AK4367VN的Datasheet PDF文件第31页  
ASAHI KASEI  
[AK4367]  
(2)-2. READ Operations  
Set the R/W bit = “1” for the READ operation of the AK4367. After transmission of data, the master can read the next  
address’s data by generating an acknowledge instead of terminating the write cycle after the receipt of the first data word.  
After receiving each data packet the internal 5-bit address counter is incremented by one, and the next data is  
automatically taken into the next address. If the address exceeds 08H prior to generating a stop condition, the address  
counter will “roll over” to 00H and the previous data will be overwritten.  
The AK4367 supports two basic read operations: CURRENT ADDRESS READ and RANDOM ADDRESS READ.  
(2)-2-1. CURRENT ADDRESS READ  
The AK4367 contains an internal address counter that maintains the address of the last word accessed, incremented by  
one. Therefore, if the last access (either a read or write) were to address n, the next CURRENT READ operation would  
access data from the address n+1. After receipt of the slave address with R/W bit set to “1”, the AK4367 generates an  
acknowledge, transmits 1-byte of data to the address set by the internal address counter and increments the internal  
address counter by 1. If the master does not generate an acknowledge to the data but instead generates a stop condition,  
the AK4367 ceases transmission.  
S
S
T
O
P
T
A
R
T
R/W="1"  
Slave  
Address  
S
Data(n)  
Data(n+1)  
Data(n+2)  
Data(n+x)  
P
SDA  
A
C
K
A
C
K
A
C
K
A
C
K
A
C
K
A
C
K
Figure 26. CURRENT ADDRESS READ  
(2)-2-2. RANDOM ADDRESS READ  
The random read operation allows the master to access any memory location at random. Prior to issuing the slave address  
with the R/W bit set to “1”, the master must first perform a “dummy” write operation. The master issues a start request, a  
slave address (R/W bit = “0”) and then the register address to read. After the register address is acknowledged, the master  
immediately reissues the start request and the slave address with the R/W bit set to “1”. The AK4367 then generates an  
acknowledge, 1 byte of data and increments the internal address counter by 1. If the master does not generate an  
acknowledge to the data but instead generates a stop condition, the AK4367 ceases transmission.  
S
T
A
R
T
S
T
A
R
T
S
T
O
P
R/W="0"  
R/W="1"  
Slave  
Address  
Sub  
Address(n)  
Slave  
Address  
S
S
Data(n)  
Data(n+1)  
Data(n+x)  
P
SDA  
A
C
K
A
C
K
A
C
K
A
C
K
A
C
K
A
C
K
A
C
K
Figure 27. RANDOM ADDRESS READ  
MS0247-E-02  
2005/10  
- 27 -  
 复制成功!