Insulation and Safety Related Specifications
Parameter
Minimum External Air Gap
(clearance)
Minimum External Tracking
(creepage)
Minimum Internal Plastic Gap
(internal clearance)
Tracking Resistance
(comparative tracking index)
Isolation Group
CTI
Symbol
L(101)
L(102)
Value
7.4
8.0
0.5
Unit
mm
mm
mm
Conditions
Measured from input terminals to output terminals,
shortest distance through air.
Measured from input terminals to output terminals,
shortest distance path along body.
Through insulation distance conductor to conductor,
usually the straight line distance thickness between the
emitter and detector.
DIN IEC 112 Part 1
Material Group (DIN EN 0110-1/1997-04)
>175
IIIa
V
Absolute Maximum Ratings
Parameter
Storage Temperature
Operating Temperature
Supply Voltage
Steady-State Input Voltage
Two Second Transient Input Voltage
Output Voltage
Reference Input Voltage
Reference Input Current
Lead Solder Temperature
Solder Reflow Temperature Profile
Symbol
T
S
T
A
V
DD1_max
, V
DD1_max
V
IN+
, V
IN-
V
IN+
, V
IN-
V
OUT
V
REF
I
REF
See Package Outline Drawings section
Min.
–55
–40
0
–2.0
–6.0
–0.5
0.0
Max.
125
100
6
V
DD1
+ 0.5
-
V
DD1
+ 0.5
-
V
DD2
+ 0.5
-
V
DD2
+ 0.5
-
20
-
Units
°C
°C
V
V
V
V
V
mA
Note
260°C for 10 sec., 1.6 mm below seating plane
Recommended Operating Conditions
Parameter
Operating Temperature
Supply Voltage
Input Voltage (accurate and linear)
Input Voltage (functional)
Reference Input Voltage
Symbol
T
A
V
DD1
, V
DD2
V
IN+
, V
IN-
V
IN+
, V
IN-
V
REF
Min.
–40
4.5
–200
–2.0
4.0
Max.
85
5.5
200
2.0
V
DD2
Units
°C
V
mV
V
V
Note
6