欢迎访问ic37.com |
会员登录 免费注册
发布采购

HCPL-7510 参数 Datasheet PDF下载

HCPL-7510图片预览
型号: HCPL-7510
PDF下载: 下载PDF文件 查看货源
内容描述: 隔离线性传感IC [Isolated Linear Sensing IC]
分类和应用: 模拟IC信号电路
文件页数/大小: 16 页 / 117 K
品牌: AGILENT [ AGILENT TECHNOLOGIES, LTD. ]
 浏览型号HCPL-7510的Datasheet PDF文件第1页浏览型号HCPL-7510的Datasheet PDF文件第2页浏览型号HCPL-7510的Datasheet PDF文件第3页浏览型号HCPL-7510的Datasheet PDF文件第4页浏览型号HCPL-7510的Datasheet PDF文件第6页浏览型号HCPL-7510的Datasheet PDF文件第7页浏览型号HCPL-7510的Datasheet PDF文件第8页浏览型号HCPL-7510的Datasheet PDF文件第9页  
Regulatory Information
The HCPL-7510 has been approved by the following organizations:
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01.
UL
Approved under UL 1577, component recognition
program up to V
ISO
= 3750 V
RMS
. File E55361.
CSA
Approved under CSA Component Acceptance
Notice #5, File CA 88324.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
[1]
Description
Installation classification per DIN EN 0110-1/1997-04, Table 1
for rated mains voltage - 150 V
rms
for rated mains voltage - 300 V
rms
for rated mains voltage - 600 V
rms
Climatic Classification
Pollution Degree (DIN EN 0110-1/1997-04)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b
[2]
V
IORM
x 1.875 = V
PR
, 100% production test with t
m
= 1 sec, partial discharge <5 pC
Input to Output Test Voltage, Method a
[2]
V
IORM
x 1.5 = V
PR
, type and sample test, t
m
= 60 sec, partial discharge <5 pC
Highest Allowable Overvoltage (transient overvoltage t
ini
= 10 sec)
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature
Input Current
[3]
Output Power
[3]
Insulation Resistance at T
S
, V
IO
= 500 V
Notes:
1. Insulation characteristics are guaranteed only within the safety maximum ratings which must be
ensured by protective circuits within the application. Surface Mount Classifications is Class A in
accordance with CECC00802.
2. Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog,
under Product Safety Regulations section,
(IEC/EN/DIN EN 60747-5-2) for a detailed description of Method a and Method b partial
discharge test profiles.
3. Refer to the following figure for dependence of P
S
and I
S
on ambient temperature.
Symbol
Characteristic Unit
I – IV
I – III
I – II
55/100/21
2
V
IORM
V
PR
V
PR
V
IOTM
891
1670
1336
6000
V
peak
V
peak
V
peak
V
peak
°C
mA
mW
T
S
175
I
S, INPUT
400
P
S, OUTPUT
600
R
S
800
>10
9
OUTPUT POWER – P
S
, INPUT CURRENT – I
S
700
600
500
400
300
200
100
0
0
25
50
75
P
S
(mW)
I
S
(mA)
100 125 150 175 200
T
S
– CASE TEMPERATURE – C